Schneider Electric JGA36225YP Molded Case Circuit Breaker 600V 225A

(No reviews yet) Write a Review
SKU:
JGA36225YP
UPC:
785901457305
Condition:
New
Product Name:
PowerPact J
Quality Labels:
CE
Utilisation Category:
category A
Height:
191 mm
Breaking Capacity:
65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 20 kA 500 V DC UL 489
Ip Degree Of Protection:
front cover IP40
Depth:
86 mm
Product Or Component Type:
Motor Circuit Protector
Environmental Disclosure:
ENVPEP2206031EN
Product Certifications:
UL || CSA || NOM
Ambient Air Temperature For Storage:
-50-85 °C
Control Type:
toggle
Sustainable Offer Status:
Green Premium product
[Ith] Conventional Free Air Thermal Current:
114-217 A
Awg Gauge:
AWG 3/0...350 kcmil aluminium/copper terminals
Communication Interface:
Modbus || Ethernet
Long Time Pick-Up Adjustment Range:
0.25...1 x In
Breaking Capacity Code:
G
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz IEC 60947-3
Pvc Free:
Yes
Magnetic Hold Current:
1125 A
Pollution Degree:
3 IEC 60947-1
Eu Rohs Directive:
Compliant with Exemptions
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Local Signalling:
switched off (OFF) 1 trip indicator green)
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Suitability For Isolation:
yes IEC 60947-2
Range:
PowerPact
Ambient Air Temperature For Operation:
-2-70 °C
Wire Stripping Length:
25 mm
Width:
104 mm
Continuous Current Rating:
0.8
Electrical Connection:
I-Line connection, line || lugs, load
Accessory / Separate Part Type:
padlocking device ON and OFF end
Network Frequency:
50/60 Hz
Poles Description:
3P
Magnetic Tripping Current:
2250-2250 A
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Circularity Profile:
ENVEOLI2206031EN
Trip Unit Technology:
thermal-magnetic
Rohs Exemption Information:
Yes
Device Application:
distribution
Mounting Mode:
I-Line bracket)
Mounting Support:
bracket
Warranty:
18 months
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Protection Type:
overload protection || short-circuit protection
Terminal Identifier:
AL250JD
Net Weight:
2.4 kg
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Line Rated Current:
225-225 A
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
[Ics] Rated Service Breaking Capacity:
65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Mounting Height:
4.5 in
Mercury Free:
Yes
Tightening Torque:
25-25 N.m 95-185 mm² (AWG 3/0...350 kcmil)
Brochure:
View
Catalog:
View
Datasheet:
View
$4,045.00

Description

PowerPacT J-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT J-Frame circuit breakers are available with either thermal magnetic or MicroLogic electronic trip protection units. This PowerPacT J-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 18kA at 600VAC. All PowerPacT J-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT J circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT J I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT J, 225A, 3 pole, circuit breaker has a breaking capacity of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. This unit has a handle padlock, On or Off. PowerPacT J circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose