Schneider Electric JGF36225 Molded Case Circuit Breaker 600V 225A

(No reviews yet) Write a Review
SKU:
JGF36225
UPC:
7.85902E+11
Condition:
New
Width:
104 mm
Product Or Component Type:
circuit breaker
Poles Description:
3P
[Ics] Rated Service Breaking Capacity:
65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Line Rated Current:
225-225 A
Circuit Breaker Application:
HACR rated
Electrical Connection:
busbar connection, line || busbar connection, load
Environmental Disclosure:
ENVPEP2206031EN
Utilisation Category:
category A
Network Frequency:
50/60 Hz
Local Signalling:
switched off (OFF) 1 trip indicator green)
Product Name:
PowerPact J
Warranty:
18 months
Suitability For Isolation:
yes IEC 60947-2
Continuous Current Rating:
0.8
Ip Degree Of Protection:
front cover IP40
Ambient Air Temperature For Operation:
-2-70 °C
Sustainable Offer Status:
Green Premium product
Tightening Torque:
25-25 N.m 95-185 mm² (AWG 3/0...350 kcmil)
Range:
PowerPact
Depth:
86 mm
Circularity Profile:
ENVEOLI2206031EN
Communication Interface:
Modbus || Ethernet
Breaking Capacity Code:
G
Rohs Exemption Information:
Yes
Magnetic Tripping Current:
2250-2250 A
Breaking Capacity:
65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 20 kA 500 V DC UL 489
Mercury Free:
Yes
Mounting Support:
busbar
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Control Type:
toggle
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Pvc Free:
Yes
Trip Unit Technology:
thermal-magnetic
Wire Stripping Length:
25 mm
Quality Labels:
CE
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Net Weight:
2.4 kg
Long Time Pick-Up Adjustment Range:
0.25...1 x In
Eu Rohs Directive:
Compliant with Exemptions
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Terminal Identifier:
AL250JD
Product Certifications:
UL || CSA || NOM
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz IEC 60947-3
Ambient Air Temperature For Storage:
-50-85 °C
Height:
191 mm
Protection Type:
overload protection || short-circuit protection
Pollution Degree:
3 IEC 60947-1
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Mounting Mode:
unit mount busbar)
Device Application:
distribution
Awg Gauge:
AWG 3/0...350 kcmil aluminium/copper terminals
Magnetic Hold Current:
1125 A
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
  • Schneider Electric JGF36225 Molded Case Circuit Breaker 600V 225A
  • Schneider Electric JGF36225 Molded Case Circuit Breaker 600V 225A
$5,668.50

Description

PowerPacT J-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT J-Frame circuit breakers are available with either thermal magnetic or MicroLogic electronic trip protection units. This PowerPacT J-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 18kA at 600VAC. All PowerPacT J-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT J circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has a busbar connection. This PowerPacT J, 225A, 3 pole, circuit breaker has a breaking capacity of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT J circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose