Schneider Electric JGL36225 Molded Case Circuit Breaker 600V 225A

(No reviews yet) Write a Review
SKU:
JGL36225
UPC:
785901883760
Condition:
New
Rohs Exemption Information:
Yes
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Utilisation Category:
category A
Product Name:
PowerPact J
[Ics] Rated Service Breaking Capacity:
65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz IEC 60947-3
Network Frequency:
50/60 Hz
Eu Rohs Directive:
Compliant with Exemptions
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Mercury Free:
Yes
Pvc Free:
Yes
Magnetic Tripping Current:
2250-2250 A
Sustainable Offer Status:
Green Premium product
Depth:
86 mm
Product Or Component Type:
circuit breaker
Long Time Pick-Up Adjustment Range:
0.25...1 x In
Circuit Breaker Application:
HACR rated
Breaking Capacity:
65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 20 kA 500 V DC UL 489
Pollution Degree:
3 IEC 60947-1
Trip Unit Technology:
thermal-magnetic
Awg Gauge:
AWG 3/0...350 kcmil aluminium/copper terminals
Environmental Disclosure:
ENVPEP2206031EN
Protection Type:
overload protection || short-circuit protection
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Mounting Mode:
unit mount lug)
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Tightening Torque:
25-25 N.m 95-185 mm² (AWG 3/0...350 kcmil)
Communication Interface:
Modbus || Ethernet
Device Application:
distribution
Width:
104 mm
Terminal Identifier:
AL250JD
Control Type:
toggle
Range:
PowerPact
Net Weight:
2.4 kg
Product Certifications:
UL || CSA || NOM
Poles Description:
3P
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Ambient Air Temperature For Operation:
-2-70 °C
Warranty:
18 months
Ambient Air Temperature For Storage:
-50-85 °C
Magnetic Hold Current:
1125 A
Electrical Connection:
lugs, line || lugs, load
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Ip Degree Of Protection:
front cover IP40
Wire Stripping Length:
25 mm
Line Rated Current:
225-225 A
Breaking Capacity Code:
G
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Mounting Support:
lug
Height:
191 mm
Continuous Current Rating:
0.8
Circularity Profile:
ENVEOLI2206031EN
Suitability For Isolation:
yes IEC 60947-2
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Quality Labels:
CE
Local Signalling:
switched off (OFF) 1 trip indicator green)
  • Schneider Electric JGL36225 Molded Case Circuit Breaker 600V 225A
  • Schneider Electric JGL36225 Molded Case Circuit Breaker 600V 225A
  • Schneider Electric JGL36225 Molded Case Circuit Breaker 600V 225A
$3,779.00

Description

PowerPacT J-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT J-Frame circuit breakers are available with either thermal magnetic or MicroLogic electronic trip protection units. This PowerPacT J-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 18kA at 600VAC. All PowerPacT J-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT J circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has lugs on both the line and load sides. This PowerPacT J, 225A, 3 pole, circuit breaker has a breaking capacity of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT J circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.