Schneider Electric JJL36200C Molded Case Circuit Breaker 600V 200A
Schneider Electric
$6,519.00
PowerPacT J-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT J-Frame circuit breakers are available with either thermal magnetic or MicroLogic electronic trip protection units. This PowerPacT J-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 25kA at 600VAC. All PowerPacT J-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT J circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has lugs on both the line and load sides. This PowerPacT J, 200A, 3 pole, circuit breaker has a breaking capacity of 25kA at 600VAC. This circuit breaker has a continuous current rating of 100%. PowerPacT J circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Protection Type:
- overload protection || short-circuit protection
- Circuit Breaker Application:
- HACR rated
- Poles Description:
- 3P
- Trip Unit Technology:
- thermal-magnetic
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Phase Connection:
- CBA
- Terminal Identifier:
- AL250JD
- Ip Degree Of Protection:
- front cover IP40
- Pvc Free:
- Yes
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Height:
- 191 mm
- Network Frequency:
- 50/60 Hz
- Sustainable Offer Status:
- Green Premium product
- Warranty:
- 18 months
- Line Rated Current:
- 200-200 A
- Width:
- 104 mm
- Product Name:
- PowerPact J
- Magnetic Hold Current:
- 1000 A
- Long Time Pick-Up Adjustment Range:
- 0.25...1 x In
- Eu Rohs Directive:
- Compliant with Exemptions
- Device Application:
- distribution
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Wire Stripping Length:
- 25 mm
- Mounting Height:
- 4.5 in
- Local Signalling:
- switched off (OFF) 1 trip indicator green)
- Continuous Current Rating:
- 1
- Breaking Capacity Code:
- J
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- [Ics] Rated Service Breaking Capacity:
- 65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- Magnetic Tripping Current:
- 2000-2000 A
- Communication Interface:
- Modbus || Ethernet
- Product Or Component Type:
- circuit breaker
- Depth:
- 86 mm
- Electrical Connection:
- lugs, line || lugs, load
- Utilisation Category:
- category A
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz IEC 60947-3
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Control Type:
- toggle
- Net Weight:
- 2.4 kg
- Ambient Air Temperature For Storage:
- -50-85 °C
- Product Certifications:
- UL || CSA || NOM
- Environmental Disclosure:
- ENVPEP2206031EN
- Quality Labels:
- CE
- Range:
- PowerPact
- Tightening Torque:
- 25-25 N.m 95-185 mm² (AWG 3/0...350 kcmil)
- Rohs Exemption Information:
- Yes
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Mounting Support:
- lug
- Pollution Degree:
- 3 IEC 60947-1
- Circularity Profile:
- ENVEOLI2206031EN
- Mounting Mode:
- unit mount lug)
- Awg Gauge:
- AWG 3/0...350 kcmil aluminium/copper terminals
- Suitability For Isolation:
- yes IEC 60947-2
- Ambient Air Temperature For Operation:
- -2-70 °C
- Mercury Free:
- Yes
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Breaking Capacity:
- 100 kA 240 V AC 50/60 Hz UL 489 || 65 kA 480 V AC 50/60 Hz UL 489 || 25 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489
- Brochure:
- View
- Catalog:
- View
- Datasheet: