Schneider Electric LDL36400U33X Molded Case Circuit Breaker 600V 400A
Schneider Electric
$5,391.00
$1200 Minimum Order for Non-stock Items or $60 Addl Schneider Handling Fee Applies
PowerPacT L-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT L-Frame circuit breakers are available with electronic trip units. All PowerPacT L-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT L circuit breakers are available in 3 and 4-pole unit mount, I-Line, and drawout constructions. This PowerPacT L, 400A, 3 pole, circuit breaker has an interrupting rating of 14kA at 600VAC. This circuit breaker provides MicroLogic Standard with a 3.3S trip unit and an LSI function. This unit has lugs on both the line and load sides. This circuit breaker has a continuous current rating of 80%. This circuit breaker has a continuous current rating of 80%. PowerPacT L circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked. PowerPacT L circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
- Ambient Air Temperature For Storage:
- -50-85 °C
- Mounting Mode:
- unit mount lug)
- Awg Gauge:
- 2 x AWG 2/0...500 kcmil aluminium/copper
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Mercury Free:
- Yes
- Pollution Degree:
- 3 IEC 60947-1
- Device Short Name:
- L-Frame
- Trip Unit Technology:
- electronic, standard, MicroLogic 3.3 S, LSI
- Width:
- 140 mm
- Suitability For Isolation:
- yes IEC 60947-2
- Eu Rohs Directive:
- Compliant with Exemptions
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz IEC 60947-3
- Product Or Component Type:
- circuit breaker
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Warranty:
- 18 months
- Wire Stripping Length:
- 31 mm || 61 mm
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Terminal Identifier:
- AL600LS52K3
- Circuit Breaker Application:
- HACR rated
- Net Weight:
- 6.2 kg
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Local Signalling:
- ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
- Breaking Capacity Code:
- D
- Control Type:
- toggle
- Utilisation Category:
- category A
- Ip Degree Of Protection:
- front cover IP40
- Communication Interface:
- Modbus || Ethernet
- Depth:
- 110 mm
- Circularity Profile:
- ENVEOLI2206029EN
- Pvc Free:
- Yes
- Sustainable Offer Status:
- Green Premium product
- Continuous Current Rating:
- 0.8
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Long Time Pick-Up Adjustment Range:
- 0.25...1 x In
- [Ics] Rated Service Breaking Capacity:
- 25 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 14 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- Tightening Torque:
- 50-50 N.m 70-240 mm² (AWG 2/0...500 kcmil)
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Breaking Capacity:
- 25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz UL 489 || 14 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489
- Color:
- Black
- Trip Unit Name:
- MicroLogic 3.3 S
- Environmental Disclosure:
- ENVPEP2206029EN
- Ambient Air Temperature For Operation:
- -2-70 °C
- Product Certifications:
- UL || CSA || NOM
- Mounting Support:
- lug
- Product Name:
- PowerPact L
- Device Application:
- distribution
- Network Frequency:
- 50/60 Hz
- Poles Description:
- 3P
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Electrical Connection:
- lugs, line || lugs, load
- Range:
- PowerPact
- Rohs Exemption Information:
- Yes
- Line Rated Current:
- 400-400 A
- Height:
- 340 mm
- Brochure:
- View
- Catalog:
- View
- Datasheet: