Schneider Electric LGA36400CU31X Molded Case Circuit Breaker 600V 400A

(No reviews yet) Write a Review
SKU:
LGA36400CU31X
UPC:
785901629405
Condition:
New
Network Frequency:
50/60 Hz
Warranty:
18 months
Eu Rohs Directive:
Compliant with Exemptions
Product Name:
PowerPact L
Net Weight:
6.2 kg
Height:
340 mm
Color:
Black
Trip Unit Name:
MicroLogic 3.3
Local Signalling:
ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
[Ics] Rated Service Breaking Capacity:
65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Environmental Disclosure:
ENVPEP2206029EN
Rohs Exemption Information:
Yes
Control Type:
toggle
Breaking Capacity Code:
G
Terminal Identifier:
AL600LS52K3
Ip Degree Of Protection:
front cover IP40
Range:
PowerPact
Long Time Pick-Up Adjustment Range:
0.25...1 x In
Product Certifications:
UL || CSA || NOM
Device Short Name:
L-Frame
Mercury Free:
Yes
Width:
140 mm
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Circuit Breaker Application:
HACR rated
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Breaking Capacity:
65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 20 kA 500 V DC UL 489
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Product Or Component Type:
circuit breaker
Wire Stripping Length:
31 mm || 61 mm
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Awg Gauge:
2 x AWG 2/0...500 kcmil aluminium/copper
Pvc Free:
Yes
Circularity Profile:
ENVEOLI2206029EN
Poles Description:
3P
Phase Connection:
ABC
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Suitability For Isolation:
yes IEC 60947-2
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Tightening Torque:
50-50 N.m 70-240 mm² (AWG 2/0...500 kcmil)
Device Application:
distribution
Electrical Connection:
I-Line connection, line || lugs, load
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz IEC 60947-3
Continuous Current Rating:
1
Ambient Air Temperature For Storage:
-50-85 °C
Trip Unit Technology:
electronic, standard, MicroLogic 3.3, LI
Sustainable Offer Status:
Green Premium product
Line Rated Current:
400-400 A
Depth:
110 mm
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Ambient Air Temperature For Operation:
-2-70 °C
Mounting Mode:
I-Line bracket)
Mounting Height:
6 in
Communication Interface:
Modbus || Ethernet
Utilisation Category:
category A
Pollution Degree:
3 IEC 60947-1
Mounting Support:
bracket
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric LGA36400CU31X Molded Case Circuit Breaker 600V 400A
  • Schneider Electric LGA36400CU31X Molded Case Circuit Breaker 600V 400A
  • Schneider Electric LGA36400CU31X Molded Case Circuit Breaker 600V 400A
$6,240.00

Description

PowerPacT L-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT L-Frame circuit breakers are available with electronic trip units. All PowerPacT L-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT L circuit breakers are available in 3 and 4-pole unit mount, I-Line, and drawout constructions. This PowerPacT L, 400A, 3 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker provides MicroLogic Standard with a 3.3 trip unit and an LI function. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This circuit breaker has a continuous current rating of 100% with an ABC phase connection. This circuit breaker has a continuous current rating of 100% with an ABC phase connection. PowerPacT L circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked. PowerPacT L circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose