Schneider Electric LGF36250CU33X Molded Case Circuit Breaker 600V 400A
Schneider Electric
$6,538.00
PowerPacT L-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT L-Frame circuit breakers are available with electronic trip units. All PowerPacT L-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT L circuit breakers are available in 3 and 4-pole unit mount, I-Line, and drawout constructions. This PowerPacT L, 250A, 3 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker provides MicroLogic Standard with a 3.3S trip unit and an LSI function. This unit has a busbar connection. This circuit breaker has a continuous current rating of 100%. PowerPacT L circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
- Wire Stripping Length:
- 31 mm
- Width:
- 140 mm
- Terminal Identifier:
- AL400L61K3
- Product Name:
- PowerPact L
- Net Weight:
- 6.2 kg
- Warranty:
- 18 months
- Height:
- 340 mm
- Eu Rohs Directive:
- Compliant with Exemptions
- Ip Degree Of Protection:
- front cover IP40
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Mounting Support:
- busbar
- Depth:
- 110 mm
- Device Application:
- distribution
- Pvc Free:
- Yes
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Local Signalling:
- ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
- Ambient Air Temperature For Storage:
- -50-85 °C
- Mercury Free:
- Yes
- Utilisation Category:
- category A
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz IEC 60947-3
- Network Frequency:
- 50/60 Hz
- Poles Description:
- 3P
- Ambient Air Temperature For Operation:
- -2-70 °C
- Tightening Torque:
- 50-50 N.m 35-300 mm² (AWG 2...600 kcmil) || 50-50 N.m 35-240 mm² (AWG 2...500 kcmil)
- Awg Gauge:
- AWG 2...600 kcmil copper || AWG 2...500 kcmil aluminium
- Mounting Mode:
- unit mount busbar)
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Suitability For Isolation:
- yes IEC 60947-2
- Continuous Current Rating:
- 1
- Breaking Capacity:
- 65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 20 kA 500 V DC UL 489
- Protection Technology:
- current limiter
- Control Type:
- toggle
- Circularity Profile:
- ENVEOLI2206029EN
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Trip Unit Name:
- MicroLogic 3.3 S
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Circuit Breaker Application:
- HACR rated
- Environmental Disclosure:
- ENVPEP2206029EN
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Pollution Degree:
- 3 IEC 60947-1
- Product Or Component Type:
- circuit breaker
- Range:
- PowerPact
- Device Short Name:
- L-Frame
- Trip Unit Technology:
- electronic, standard, MicroLogic 3.3 S, LSI
- Long Time Pick-Up Adjustment Range:
- 0.25...1 x In
- Color:
- Black
- Rohs Exemption Information:
- Yes
- Communication Interface:
- Modbus || Ethernet
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Product Certifications:
- UL || CSA || NOM
- Breaking Capacity Code:
- G
- Electrical Connection:
- busbar connection, line || busbar connection, load
- Sustainable Offer Status:
- Green Premium product
- [Ics] Rated Service Breaking Capacity:
- 65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- Line Rated Current:
- 250-250 A
- Brochure:
- View
- Catalog:
- View
- Datasheet:
- View