Schneider Electric LHL364001021 Molded Case Circuit Breaker 600V 400A

(No reviews yet) Write a Review
SKU:
LHL364001021
UPC:
785901845942
Condition:
New
Pvc Free:
Yes
Rohs Exemption Information:
Yes
Magnetic Hold Current:
2000 A
Environmental Disclosure:
ENVPEP1410004EN
Circuit Breaker Application:
HACR rated
Sustainable Offer Status:
Green Premium product
Terminal Identifier:
AL400LA
Warranty:
18 months
Width:
6 in
Trip Unit Technology:
thermal-magnetic
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Mercury Free:
Yes
Circularity Profile:
N/A
Breaking Capacity Code:
H
Electrical Connection:
lugs, load || lugs, line
Magnetic Tripping Current:
4000-4000 A
Mounting Mode:
unit mount
Tightening Torque:
13-13 N.m 42-304 mm² (AWG 1...600 kcmil) || 13-13 N.m 42-127 mm² (AWG 1...250 kcmil)
Product Certifications:
CSA || IEC || UL Listed
Depth:
5.84 in
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Halogen Content Performance:
Halogen free plastic parts product
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Device Application:
distribution
Height:
11 in
Eu Rohs Directive:
Compliant with Exemptions
Poles Description:
3P
Product Or Component Type:
circuit breaker
Line Rated Current:
400 A
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric LHL364001021 Molded Case Circuit Breaker 600V 400A
  • Schneider Electric LHL364001021 Molded Case Circuit Breaker 600V 400A
  • Schneider Electric LHL364001021 Molded Case Circuit Breaker 600V 400A
$12,756.00

Description

Square D LH molded case circuit breakers provide thermal magnetic protection. Their primary function is automatic opening of a circuit under overload or short circuit conditions or manual opening. LH circuit breakers contain thermal (overload) and magnetic (short circuit) sensing elements in each pole. Push-to-Trip allows the circuit breaker to be manually tripped without exposure to live parts. This Square D LH molded case circuit breaker is a 3 pole unit mount breaker, 400A and 600VAC. The thermal magnetic circuit breaker has an interrupting rating of 25kA for 600VAC and 50kA for 250VDC. The circuit breaker 1021 suffix indicates a factory installed shunt trip. LH breakers are UL 489, CSA, IEC certified.