Schneider Electric LJA36600U31X Molded Case Circuit Breaker 600V 600A
Schneider Electric
$10,836.00
PowerPacT L-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT L-Frame circuit breakers are available with electronic trip units. All PowerPacT L-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT L circuit breakers are available in 3 and 4-pole unit mount, I-Line, and drawout constructions. This PowerPacT L, 600A, 3 pole, circuit breaker has an interrupting rating of 25kA at 600VAC. This circuit breaker provides MicroLogic Standard with a 3.3 trip unit and an LI function. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT L circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked. PowerPacT L circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Local Signalling:
- ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
- Terminal Identifier:
- AL600LF52K3
- Electrical Connection:
- I-Line connection, line || lugs, load
- Product Name:
- PowerPact L
- Trip Unit Name:
- MicroLogic 3.3
- Product Or Component Type:
- circuit breaker
- Breaking Capacity:
- 100 kA 240 V AC 50/60 Hz UL 489 || 65 kA 480 V AC 50/60 Hz UL 489 || 25 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489
- Phase Connection:
- ABC
- Circuit Breaker Application:
- HACR rated
- Warranty:
- 18 months
- Circularity Profile:
- ENVEOLI2206029EN
- Height:
- 340 mm
- Utilisation Category:
- category A
- Depth:
- 110 mm
- Rohs Exemption Information:
- Yes
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Trip Unit Technology:
- electronic, standard, MicroLogic 3.3, LI
- Network Frequency:
- 50/60 Hz
- Breaking Capacity Code:
- J
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Tightening Torque:
- 50-50 N.m 70-240 mm² (2 x AWG 2/0...500 kcmil)
- Product Certifications:
- UL || CSA || NOM
- Net Weight:
- 6.2 kg
- Pollution Degree:
- 3 IEC 60947-1
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz IEC 60947-3
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Range:
- PowerPact
- Poles Description:
- 3P
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Wire Stripping Length:
- 31 mm
- Suitability For Isolation:
- yes IEC 60947-2
- Ambient Air Temperature For Storage:
- -50-85 °C
- Device Short Name:
- L-Frame
- Ambient Air Temperature For Operation:
- -2-70 °C
- Control Type:
- toggle
- Width:
- 140 mm
- Protection Technology:
- current limiter
- Eu Rohs Directive:
- Compliant with Exemptions
- Long Time Pick-Up Adjustment Range:
- 0.25...1 x In
- Sustainable Offer Status:
- Green Premium product
- Ip Degree Of Protection:
- front cover IP40
- Mounting Height:
- 6 in
- Pvc Free:
- Yes
- Communication Interface:
- Modbus || Ethernet
- [Ics] Rated Service Breaking Capacity:
- 65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- Continuous Current Rating:
- 0.8
- Mercury Free:
- Yes
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Line Rated Current:
- 600-600 A
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Device Application:
- distribution
- Mounting Mode:
- I-Line bracket)
- Awg Gauge:
- 2 x AWG 2/0...500 kcmil aluminium/copper
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Environmental Disclosure:
- ENVPEP2206029EN
- Mounting Support:
- bracket
- Color:
- Black
- Brochure:
- View
- Catalog:
- View
- Datasheet:
- View