Schneider Electric LJL36600M37X Molded Case Circuit Breaker 600V 600A

(No reviews yet) Write a Review
SKU:
LJL36600M37X
UPC:
785901954644
Condition:
New
Device Short Name:
L-Frame
Pollution Degree:
3 IEC 60947-1
Environmental Disclosure:
ENVPEP2206029EN
Trip Unit Name:
MicroLogic 1.3 M
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Ambient Air Temperature For Storage:
-50-85 °C
Width:
140 mm
Breaking Capacity Code:
J
Magnetic Tripping Current:
500-1200 A
Wire Stripping Length:
31 mm || 61 mm
[Ics] Rated Service Breaking Capacity:
65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Network Frequency:
50/60 Hz
Circularity Profile:
ENVEOLI2206029EN
Mounting Mode:
unit mount lug)
Product Name:
PowerPact L
Terminal Identifier:
AL600LS52K3
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Control Type:
toggle
Tightening Torque:
50-50 N.m 70-240 mm² (AWG 2/0...500 kcmil)
Suitability For Isolation:
yes IEC 60947-2
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Circuit Breaker Application:
HACR rated
Poles Description:
3P
Pvc Free:
Yes
Electrical Connection:
lugs, line || lugs, load
Device Application:
distribution
Breaking Capacity:
100 kA 240 V AC 50/60 Hz UL 489 || 65 kA 480 V AC 50/60 Hz UL 489 || 25 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Communication Interface:
Modbus || Ethernet
Eu Rohs Directive:
Compliant with Exemptions
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Color:
Black
Awg Gauge:
2 x AWG 2/0...500 kcmil aluminium/copper
Height:
340 mm
Sustainable Offer Status:
Green Premium product
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Protection Technology:
current limiter
Mercury Free:
Yes
Warranty:
18 months
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz IEC 60947-3
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Utilisation Category:
category A
Ambient Air Temperature For Operation:
-2-70 °C
Product Certifications:
UL || CSA || NOM
Net Weight:
6.2 kg
Depth:
110 mm
Ip Degree Of Protection:
front cover IP40
Mounting Support:
lug
Product Or Component Type:
Motor Circuit Protector
Range:
PowerPact
Local Signalling:
ready 1 LED green) || switched off (OFF) 1 trip indicator green)
Trip Unit Technology:
electronic, standard, MicroLogic 1.3 M, I
Line Rated Current:
600-600 A
Rohs Exemption Information:
Yes
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric LJL36600M37X Molded Case Circuit Breaker 600V 600A
  • Schneider Electric LJL36600M37X Molded Case Circuit Breaker 600V 600A
  • Schneider Electric LJL36600M37X Molded Case Circuit Breaker 600V 600A
$6,949.00

Description

PowerPacT L-Frame motor circuit protectors (MCP) are instantaneous-trip circuit breakers designed to offer short circuit protection for motors. PowerPacT L-Frame motor circuit protectors are available with electronic trip units. The unique design of the PowerPacT MCPs accommodates transient motor inrush current without nuisance tripping. These motor protectors accept the same accessories and terminals as the equivalent PowerPacT L circuit breaker. PowerPacT L protectors are available in 3 pole unit mount, I-Line, and plug in constructions. This PowerPacT L, 600A, 3 pole, MCP has an interrupting rating of 25kA at 600VAC. This protector provides MicroLogic with a 1.3M trip unit. This unit has lugs on both the line and load sides. This motor circuit protector has a continuous current rating of 80%. PowerPacT L motor circuit protectors comply to UL, CSA, and IEC standards.
View AllClose