Schneider Electric LLA36400U31X Molded Case Circuit Breaker 600V 400A

(No reviews yet) Write a Review
SKU:
LLA36400U31X
UPC:
785901401308
Condition:
New
Trip Unit Name:
MicroLogic 3.3
Utilisation Category:
category A
Mercury Free:
Yes
Environmental Disclosure:
ENVPEP2206029EN
Width:
140 mm
Phase Connection:
ABC
Local Signalling:
ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
Suitability For Isolation:
yes IEC 60947-2
Sustainable Offer Status:
Green Premium product
Circuit Breaker Application:
HACR rated
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Terminal Identifier:
AL600LF52K3
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Mounting Support:
bracket
Line Rated Current:
400-400 A
Tightening Torque:
50-50 N.m 95-240 mm² (AWG 3/0...500 kcmil)
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Ip Degree Of Protection:
front cover IP40
Breaking Capacity:
125 kA 240 V AC 50/60 Hz UL 489 || 100 kA 480 V AC 50/60 Hz UL 489 || 50 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 50 kA 500 V DC UL 489
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Range:
PowerPact
Height:
340 mm
Circularity Profile:
ENVEOLI2206029EN
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Breaking Capacity Code:
L
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Product Or Component Type:
circuit breaker
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Net Weight:
6.2 kg
Mounting Height:
6 in
Poles Description:
3P
Control Type:
toggle
Trip Unit Technology:
electronic, standard, MicroLogic 3.3, LI
Color:
Black
Depth:
110 mm
Ambient Air Temperature For Storage:
-50-85 °C
Long Time Pick-Up Adjustment Range:
0.25...1 x In
Awg Gauge:
AWG 3/0...500 kcmil aluminium/copper
Product Name:
PowerPact L
Rohs Exemption Information:
Yes
Device Application:
distribution
Electrical Connection:
I-Line connection, line || lugs, load
Pollution Degree:
3 IEC 60947-1
Network Frequency:
50/60 Hz
Product Certifications:
UL || CSA || NOM
Pvc Free:
Yes
Continuous Current Rating:
0.8
Eu Rohs Directive:
Compliant with Exemptions
Communication Interface:
Modbus || Ethernet
Mounting Mode:
I-Line bracket)
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz IEC 60947-3
[Ics] Rated Service Breaking Capacity:
125 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 100 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 50 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Ambient Air Temperature For Operation:
-2-70 °C
Warranty:
18 months
Wire Stripping Length:
31 mm
Device Short Name:
L-Frame
Protection Technology:
current limiter
  • Schneider Electric LLA36400U31X Molded Case Circuit Breaker 600V 400A
  • Schneider Electric LLA36400U31X Molded Case Circuit Breaker 600V 400A
  • Schneider Electric LLA36400U31X Molded Case Circuit Breaker 600V 400A
$10,213.00

Description

PowerPacT L-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT L-Frame circuit breakers are available with electronic trip units. All PowerPacT L-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT L circuit breakers are available in 3 and 4-pole unit mount, I-Line, and drawout constructions. This PowerPacT L, 400A, 3 pole, circuit breaker has an interrupting rating of 50kA at 600VAC. This circuit breaker provides MicroLogic Standard with a 3.3 trip unit and an LI function. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT L circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked. PowerPacT L circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose