Schneider Electric LLA36400U43X Molded Case Circuit Breaker 600V 400A
Schneider Electric
$11,714.00
PowerPacT L-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT L-Frame circuit breakers are available with electronic trip units. All PowerPacT L-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT L circuit breakers are available in 3 and 4-pole unit mount, I-Line, and drawout constructions. This PowerPacT L, 400A, 3 pole, circuit breaker has an interrupting rating of 50kA at 600VAC. This circuit breaker provides MicroLogic Ammeter with a 5.3A trip unit and an LSI function. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT L circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
- Communication Interface:
- Modbus || Ethernet
- Awg Gauge:
- AWG 3/0...500 kcmil aluminium/copper
- Mercury Free:
- Yes
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Pvc Free:
- Yes
- Suitability For Isolation:
- yes IEC 60947-2
- Product Certifications:
- UL || CSA || NOM
- Range:
- PowerPact
- Line Rated Current:
- 400-400 A
- Height:
- 340 mm
- Circuit Breaker Application:
- HACR rated
- Ambient Air Temperature For Operation:
- -2-70 °C
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Depth:
- 110 mm
- Eu Rohs Directive:
- Compliant with Exemptions
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz IEC 60947-3
- Continuous Current Rating:
- 0.8
- Trip Unit Technology:
- electronic, ammeter, MicroLogic 5.3 A, LSI
- Phase Connection:
- ABC
- [Ics] Rated Service Breaking Capacity:
- 125 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 100 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 50 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- Control Type:
- toggle
- Environmental Disclosure:
- ENVPEP2206029EN
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Width:
- 140 mm
- Breaking Capacity Code:
- L
- Net Weight:
- 6.2 kg
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Mounting Height:
- 6 in
- Sustainable Offer Status:
- Green Premium product
- Breaking Capacity:
- 125 kA 240 V AC 50/60 Hz UL 489 || 100 kA 480 V AC 50/60 Hz UL 489 || 50 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 50 kA 500 V DC UL 489
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Mounting Support:
- bracket
- Ambient Air Temperature For Storage:
- -50-85 °C
- Electrical Connection:
- I-Line connection, line || lugs, load
- Poles Description:
- 3P
- Warranty:
- 18 months
- Tightening Torque:
- 50-50 N.m 95-240 mm² (AWG 3/0...500 kcmil)
- Circularity Profile:
- ENVEOLI2206029EN
- Product Or Component Type:
- circuit breaker
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Wire Stripping Length:
- 31 mm
- Utilisation Category:
- category A
- Network Frequency:
- 50/60 Hz
- Device Application:
- distribution
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Pollution Degree:
- 3 IEC 60947-1
- Device Short Name:
- L-Frame
- Color:
- Black
- Terminal Identifier:
- AL600LF52K3
- Product Name:
- PowerPact L
- Rohs Exemption Information:
- Yes
- Long Time Pick-Up Adjustment Range:
- 0.25...1 x In
- Protection Technology:
- current limiter
- Ip Degree Of Protection:
- front cover IP40
- Local Signalling:
- ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
- Trip Unit Name:
- MicroLogic 5.3 A
- Mounting Mode:
- I-Line bracket)