Schneider Electric LLL36400U43X Molded Case Circuit Breaker 600V 400A
Schneider Electric
$11,419.00
$1200 Minimum Order for Non-stock Items or $60 Addl Schneider Handling Fee Applies
PowerPacT L-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT L-Frame circuit breakers are available with electronic trip units. All PowerPacT L-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT L circuit breakers are available in 3 and 4-pole unit mount, I-Line, and drawout constructions. This PowerPacT L, 400A, 3 pole, circuit breaker has an interrupting rating of 50kA at 600VAC. This circuit breaker provides MicroLogic Ammeter with a 5.3A trip unit and an LSI function. This unit has lugs on both the line and load sides. This circuit breaker has a continuous current rating of 80%. PowerPacT L circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
- Control Type:
- toggle
- Range:
- PowerPact
- Pollution Degree:
- 3 IEC 60947-1
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Continuous Current Rating:
- 0.8
- Mounting Support:
- lug
- Mounting Mode:
- unit mount lug)
- Product Name:
- PowerPact L
- Height:
- 340 mm
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Device Application:
- distribution
- Poles Description:
- 3P
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Ambient Air Temperature For Operation:
- -2-70 °C
- Circularity Profile:
- ENVEOLI2206029EN
- Trip Unit Name:
- MicroLogic 5.3 A
- Ambient Air Temperature For Storage:
- -50-85 °C
- Wire Stripping Length:
- 31 mm || 61 mm
- Breaking Capacity:
- 125 kA 240 V AC 50/60 Hz UL 489 || 100 kA 480 V AC 50/60 Hz UL 489 || 50 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 50 kA 500 V DC UL 489
- Rohs Exemption Information:
- Yes
- Product Certifications:
- UL || CSA || NOM
- Circuit Breaker Application:
- HACR rated
- Electrical Connection:
- lugs, line || lugs, load
- Local Signalling:
- ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Terminal Identifier:
- AL600LS52K3
- Tightening Torque:
- 50-50 N.m 70-240 mm² (AWG 2/0...500 kcmil)
- Ip Degree Of Protection:
- front cover IP40
- Sustainable Offer Status:
- Green Premium product
- Environmental Disclosure:
- ENVPEP2206029EN
- Trip Unit Technology:
- electronic, ammeter, MicroLogic 5.3 A, LSI
- Pvc Free:
- Yes
- Device Short Name:
- L-Frame
- Eu Rohs Directive:
- Compliant with Exemptions
- Suitability For Isolation:
- yes IEC 60947-2
- Line Rated Current:
- 400-400 A
- [Ics] Rated Service Breaking Capacity:
- 125 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 100 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 50 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- Long Time Pick-Up Adjustment Range:
- 0.25...1 x In
- Warranty:
- 18 months
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Network Frequency:
- 50/60 Hz
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Product Or Component Type:
- circuit breaker
- Awg Gauge:
- 2 x AWG 2/0...500 kcmil aluminium/copper
- Communication Interface:
- Modbus || Ethernet
- Mercury Free:
- Yes
- Net Weight:
- 6.2 kg
- Width:
- 140 mm
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz IEC 60947-3
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Depth:
- 110 mm
- Color:
- Black
- Utilisation Category:
- category A
- Breaking Capacity Code:
- L
- Protection Technology:
- current limiter
- Brochure:
- View
- Catalog:
- View
- Datasheet:
- View