Schneider Electric LV429490 Vigi 440V-550V 3P For Nsx100/160

(No reviews yet) Write a Review
SKU:
LV429490
UPC:
3606481298560
Condition:
New
Maximum Breaking Time:
800 ms
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
[Ue] Rated Operational Voltage:
440...550 V AC 50/60 Hz IEC 60947-2
Device Application:
wiring
Range Compatibility:
ComPacT new generation ComPacT NSX100 new generation circuit breaker || ComPacT new generation ComPacT NSX160 new generation circuit breaker || ComPact ComPact NSX100 circuit breaker || ComPact ComPact NSX160 circuit breaker
Network Type:
AC
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Earth-Leakage Sensitivity:
0.03 A class A || 0.1 A class A || 0.3 A class A || 0.5 A class A || 1 A class A || 3 A class A || 10 A class AC || 30 A class AC
Circularity Profile:
ENVEOLI2309055EN
Residual Earth-Leakage Sensitity Adjustment Type:
adjustable
Sustainable Offer Status:
Green Premium product
Range Of Product:
ComPacT NSX100...250 new generation || ComPact NSX100...250
Eu Rohs Directive:
Compliant with Exemptions
Electrical Shock Protection Class:
class II
[Δt] Residual Earth-Leakage Time Delay Adjustment:
0-0 ms || 60-60 ms || 150-150 ms || 300-300 ms || 500-500 ms || 800-800 ms || 1.2-1.2 s || 4-4 s
Earth-Leakage Protection:
with
Environmental Disclosure:
ENVPEP2309055EN
Network Frequency:
50/60 Hz
Device Short Name:
VigiPacT
Overvoltage Category:
IV
Standards:
IEC 60947-2
Rohs Exemption Information:
Yes
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Earth-Leakage Protection Class:
class A || class AC
Product Or Component Type:
Vigi add-on
Mercury Free:
Yes
Residual Earth-Leakage Time Delay Adjustment Type:
adjustable
Line Rated Current:
100 A || 160 A
Poles Description:
3P
Datasheet:
View
$1,800.00

Description

This is a Vigi add-on module for ComPact NSX 100/160 that provides an earth-leakage protection. It is used for 3 poles circuit breakers. The operational rated voltage is between 440 and 550 VAC 50/60 Hz. The earth-leakage sensitivity is adjustable from 30 mA to 30 A. It is installed directly on the device terminals and directly actuates the trip unit in case of earth-leakage default. This Vigi add-on module is self-powered internally by the distribution-system voltage, even is supplied by only 2 phases. It is compliant with IEC 60947-2 standard, annex B.
View AllClose