Schneider Electric MGL26600 Molded Case Circuit Breaker 600V 600A

(No reviews yet) Write a Review
SKU:
MGL26600
UPC:
785901507604
Condition:
New
Product Or Component Type:
circuit breaker
Height:
12.86 in
Width:
8.27 in
Local Signalling:
1 trip indicator green)
Wire Stripping Length:
25 mm
Electrical Connection:
lugs, load || lugs, line
Depth:
8.05 in
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Net Weight:
29 lb(US)
Rohs Exemption Information:
Yes
Color:
Black
Poles Description:
2P
Pollution Degree:
3 IEC 60947-1
Pvc Free:
Yes
Trip Unit Technology:
electronic, basic, ET 1.0,
Sustainable Offer Status:
Green Premium product
Range:
PowerPact
Ambient Air Temperature For Operation:
-25-70 °C
Trip Unit Name:
ET 1.0
Suitability For Isolation:
yes IEC 60947-2
Ambient Air Temperature For Storage:
-50-85 °C
Ip Degree Of Protection:
IP40
Quantity Per Set:
1
Terminal Identifier:
AL800M23K
Mounting Mode:
unit mount lug)
Circularity Profile:
ENVEOLI2206030EN
Long Time Pick-Up Adjustment Range:
300...800 A
Mounting Support:
lug
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Circuit Breaker Application:
HACR rated
Breaking Capacity Code:
G
Mercury Free:
Yes
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Environmental Disclosure:
ENVPEP2206030EN
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Network Frequency:
50/60 Hz
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Product Certifications:
UL || CSA || NOM
Line Rated Current:
600-600 A
Control Type:
operating handle
Eu Rohs Directive:
Compliant with Exemptions
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 voltage release MN or MX plug-in)
Magnetic Tripping Current:
1200-6000 A
Product Name:
PowerPact M
Continuous Current Rating:
0.8
Awg Gauge:
3 x AWG 3/0...3 x 500 kcmil aluminium/copper
Utilisation Category:
category A
Device Application:
distribution
Quality Labels:
CE
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Tightening Torque:
50-50 N.m 95-240 mm² (3 x AWG 3/0...3 x 500 kcmil)
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Breaking Capacity:
AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 35 kA 480 V AC 50/60 Hz UL 489 || AIR 18 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2
[Ics] Rated Service Breaking Capacity:
25 kA 240 V AC 50/60 Hz IEC 60947-2 || 20 kA 380/415 V AC 50/60 Hz IEC 60947-2
Warranty:
18 months
  • Schneider Electric MGL26600 Molded Case Circuit Breaker 600V 600A
  • Schneider Electric MGL26600 Molded Case Circuit Breaker 600V 600A
  • Schneider Electric MGL26600 Molded Case Circuit Breaker 600V 600A
$5,960.00

Description

PowerPacT M-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT M-Frame circuit breakers have either a fixed long time electronic trip unit or an adjustable amperage version. This circuit breaker has an electronic trip unit, ET 1.0. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT M circuit breakers are available in 2 and 3-pole unit mount or I-Line construction. This unit has lugs on both the line and load sides. This PowerPacT M, 600A, 2 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT M circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose