Schneider Electric MGL26800E10 Molded Case Circuit Breaker 600V 800A

(No reviews yet) Write a Review
SKU:
MGL26800E10
UPC:
3606482208568
Condition:
New
Communication Interface:
Modbus
Width:
8.27 in
Poles Description:
2P
Mercury Free:
Yes
Suitability For Isolation:
yes IEC 60947-2
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Terminal Identifier:
AL800M23K
Device Application:
distribution
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Color:
Black
Breaking Capacity Code:
G
Ambient Air Temperature For Storage:
-50-85 °C
Electrical Connection:
lugs, load || lugs, line
Line Rated Current:
300-800 A
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Circularity Profile:
ENVEOLI2206030EN
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
[Ics] Rated Service Breaking Capacity:
25 kA 240 V AC 50/60 Hz IEC 60947-2 || 20 kA 380/415 V AC 50/60 Hz IEC 60947-2
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 voltage release MN or MX plug-in)
Trip Unit Technology:
electronic, basic, ET 1.0,
Environmental Disclosure:
ENVPEP2206030EN
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Awg Gauge:
3 x AWG 3/0...3 x 500 kcmil aluminium/copper
Mounting Support:
lug
Quantity Per Set:
1
Tightening Torque:
50-50 N.m 95-240 mm² (3 x AWG 3/0...3 x 500 kcmil)
Ip Degree Of Protection:
IP40
Eu Rohs Directive:
Compliant with Exemptions
Continuous Current Rating:
0.8
Network Frequency:
50/60 Hz
Local Signalling:
1 trip indicator green)
Long Time Pick-Up Adjustment Range:
300...800 A
Trip Unit Name:
ET 1.0
Wire Stripping Length:
25 mm
Magnetic Tripping Current:
1600-8000 A
Range:
PowerPact
Product Or Component Type:
circuit breaker
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Mounting Mode:
unit mount lug)
Product Certifications:
UL || CSA || NOM
Circuit Breaker Application:
HACR rated
Sustainable Offer Status:
Green Premium product
Net Weight:
29 lb(US)
Accessory / Separate Part Type:
communication module
Ambient Air Temperature For Operation:
-25-70 °C
Depth:
8.05 in
Pollution Degree:
3 IEC 60947-1
Quality Labels:
CE
Product Name:
PowerPact M
Breaking Capacity:
AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 35 kA 480 V AC 50/60 Hz UL 489 || AIR 18 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2
Height:
12.86 in
Rohs Exemption Information:
Yes
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Control Type:
operating handle
Utilisation Category:
category A
Pvc Free:
Yes
  • Schneider Electric MGL26800E10 Molded Case Circuit Breaker 600V 800A
  • Schneider Electric MGL26800E10 Molded Case Circuit Breaker 600V 800A
  • Schneider Electric MGL26800E10 Molded Case Circuit Breaker 600V 800A
$7,719.00

Description

PowerPacT M-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT M-Frame circuit breakers have either a fixed long time electronic trip unit or an adjustable amperage version. This circuit breaker has the adjustable amperage option, allowing trip setting changes between 300A to 800A using a selector switch. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT M circuit breakers are available in 2 and 3-pole unit mount or I-Line construction. This unit has lugs on both the line and load sides. This PowerPacT M, 300A to 800A, 2 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT M circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose