[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Net Weight:
29 lb(US)
Mounting Height:
9 in
Suitability For Isolation:
yes IEC 60947-2
Product Name:
PowerPact M
Device Application:
distribution
Quality Labels:
CE
Rohs Exemption Information:
Yes
Utilisation Category:
category A
Breaking Capacity Code:
J
Pvc Free:
Yes
Circularity Profile:
ENVEOLI2206030EN
Range:
PowerPact
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Magnetic Tripping Current:
1600-8000 A
Ip Degree Of Protection:
IP40
Continuous Current Rating:
0.8
Product Or Component Type:
circuit breaker
Mounting Mode:
I-Line bracket)
Ambient Air Temperature For Operation:
-25-70 °C
[Ics] Rated Service Breaking Capacity:
35 kA 240 V AC 50/60 Hz IEC 60947-2 || 25 kA 380/415 V AC 50/60 Hz IEC 60947-2
Quantity Per Set:
1
Line Rated Current:
300-800 A
Control Type:
operating handle
Sustainable Offer Status:
Green Premium product
Depth:
8.05 in
Pollution Degree:
3 IEC 60947-1
Long Time Pick-Up Adjustment Range:
300...800 A
Electrical Connection:
I-Line connection, line || lugs, load
Poles Description:
3P
Mercury Free:
Yes
Trip Unit Technology:
electronic, basic, ET 1.0,
Width:
8.27 in
Mounting Support:
bracket
Accessory / Separate Part Type:
communication module
Local Signalling:
1 trip indicator green)
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Trip Unit Name:
ET 1.0
Color:
Black
Tightening Torque:
50-50 N.m 95-240 mm² (3 x AWG 3/0...3 x 500 kcmil)
Environmental Disclosure:
ENVPEP2206030EN
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Network Frequency:
50/60 Hz
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Awg Gauge:
3 x AWG 3/0...3 x 500 kcmil aluminium/copper
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Eu Rohs Directive:
Compliant with Exemptions
Wire Stripping Length:
25 mm
Breaking Capacity:
AIR 100 kA 240 V AC 50/60 Hz UL 489 || AIR 65 kA 480 V AC 50/60 Hz UL 489 || AIR 25 kA 600 V AC 50/60 Hz UL 489 || Icu 65 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Ambient Air Temperature For Storage:
-50-85 °C
Height:
12.86 in
Terminal Identifier:
AL800M23K
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 voltage release MN or MX plug-in)
Communication Interface:
Modbus
Circuit Breaker Application:
HACR rated
Catalog:
View
Datasheet:
View
  • Schneider Electric MJA36800E10 Molded Case Circuit Breaker 600V 800A
  • Schneider Electric MJA36800E10 Molded Case Circuit Breaker 600V 800A
  • Schneider Electric MJA36800E10 Molded Case Circuit Breaker 600V 800A
$12,630.00

Description

PowerPacT M-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT M-Frame circuit breakers have either a fixed long time electronic trip unit or an adjustable amperage version. This circuit breaker has the adjustable amperage option, allowing trip setting changes between 300A to 800A using a selector switch. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT M circuit breakers are available in 2 and 3-pole unit mount or I-Line construction. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT M, 300A to 800A, 3 pole, circuit breaker has an interrupting rating of 25kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT M circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose