Schneider Electric MJL36600 Molded Case Circuit Breaker 600V 600A
Schneider Electric
$9,456.00
PowerPacT M-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT M-Frame circuit breakers have either a fixed long time electronic trip unit or an adjustable amperage version. This circuit breaker has an electronic trip unit, ET 1.0. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT M circuit breakers are available in 2 and 3-pole unit mount or I-Line construction. This unit has lugs on both the line and load sides. This PowerPacT M, 600A, 3 pole, circuit breaker has an interrupting rating of 25kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT M circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
- Width:
- 8.27 in
- Color:
- Black
- Device Application:
- distribution
- Utilisation Category:
- category A
- Ambient Air Temperature For Storage:
- -50-85 °C
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Suitability For Isolation:
- yes IEC 60947-2
- Net Weight:
- 29 lb(US)
- Product Or Component Type:
- circuit breaker
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Environmental Disclosure:
- ENVPEP2206030EN
- Trip Unit Name:
- ET 1.0
- Pvc Free:
- Yes
- Local Signalling:
- 1 trip indicator green)
- Eu Rohs Directive:
- Compliant with Exemptions
- Mounting Support:
- lug
- Mercury Free:
- Yes
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 voltage release MN or MX plug-in)
- Warranty:
- 18 months
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Quality Labels:
- CE
- Network Frequency:
- 50/60 Hz
- Awg Gauge:
- 3 x AWG 3/0...3 x 500 kcmil aluminium/copper
- Ambient Air Temperature For Operation:
- -25-70 °C
- Range:
- PowerPact
- Poles Description:
- 3P
- Ip Degree Of Protection:
- IP40
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Long Time Pick-Up Adjustment Range:
- 300...800 A
- Magnetic Tripping Current:
- 1200-6000 A
- Breaking Capacity Code:
- J
- Terminal Identifier:
- AL800M23K
- Tightening Torque:
- 50-50 N.m 95-240 mm² (3 x AWG 3/0...3 x 500 kcmil)
- Pollution Degree:
- 3 IEC 60947-1
- Depth:
- 8.05 in
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- [Ics] Rated Service Breaking Capacity:
- 35 kA 240 V AC 50/60 Hz IEC 60947-2 || 25 kA 380/415 V AC 50/60 Hz IEC 60947-2
- Mounting Mode:
- unit mount lug)
- Control Type:
- operating handle
- Electrical Connection:
- lugs, load || lugs, line
- Sustainable Offer Status:
- Green Premium product
- Circularity Profile:
- ENVEOLI2206030EN
- Breaking Capacity:
- AIR 100 kA 240 V AC 50/60 Hz UL 489 || AIR 65 kA 480 V AC 50/60 Hz UL 489 || AIR 25 kA 600 V AC 50/60 Hz UL 489 || Icu 65 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz UL 489
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
- Trip Unit Technology:
- electronic, basic, ET 1.0,
- Rohs Exemption Information:
- Yes
- Circuit Breaker Application:
- HACR rated
- Product Certifications:
- UL || CSA || NOM
- Height:
- 12.86 in
- Line Rated Current:
- 600-600 A
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Wire Stripping Length:
- 25 mm
- Product Name:
- PowerPact M
- Quantity Per Set:
- 1
- Continuous Current Rating:
- 0.8
- Brochure:
- View
- Catalog:
- View
- Datasheet: