Awg Gauge:
3 x AWG 3/0...500 kcmil aluminium/copper
Network Frequency:
50/60 Hz
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Terminal Identifier:
AL800M23K
Sustainable Offer Status:
Green Premium product
Mercury Free:
Yes
Tightening Torque:
50-50 N.m 95-240 mm² (3 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
Product Certifications:
UL || CSA || NOM
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Breaking Capacity Code:
G
Range:
PowerPact
Quality Labels:
CE
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Quantity Per Set:
1
Local Signalling:
overload 1 trip indicator green) || 1 trip indicator green)
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Device Application:
distribution
Trip Unit Technology:
electronic, standard, MicroLogic 3.0, LI
Electrical Connection:
busbar connection, line || busbar connection, load
Circularity Profile:
ENVEOLI2206033EN
Mounting Mode:
unit mount busbar)
Net Weight:
32 lb(US)
Warranty:
18 months
Product Or Component Type:
circuit breaker
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Trip Unit Name:
MicroLogic 3.0
Ambient Air Temperature For Storage:
-50-85 °C
Line Rated Current:
800-800 A
Height:
16.16 in
Pollution Degree:
3 IEC 60947-1
Long Time Pick-Up Adjustment Range:
0.4...1 x Ir
Eu Rohs Directive:
Compliant with Exemptions
Ip Degree Of Protection:
front cover IP40
Environmental Disclosure:
ENVPEP2206033EN
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Pvc Free:
Yes
Product Name:
PowerPact P
Circuit Breaker Application:
HACR rated
[Ics] Rated Service Breaking Capacity:
25 kA 240 V AC 50/60 Hz IEC 60947-2 || 20 kA 380/415 V AC 50/60 Hz IEC 60947-2
Ambient Air Temperature For Operation:
-2-70 °C
Poles Description:
3P
Rohs Exemption Information:
Yes
Depth:
8.05 in
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Width:
8.27 in
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Control Type:
toggle
Mounting Support:
busbar
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Breaking Capacity:
AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 35 kA 480 V AC 50/60 Hz UL 489 || AIR 18 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2
Continuous Current Rating:
0.8
Wire Stripping Length:
25 mm
Brochure:
View
Catalog:
View
Datasheet:
View
$14,693.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Standard with a 3.0 trip unit and an LI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has a busbar connection. This PowerPacT P, 800A, 3 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.