Schneider Electric PGF36120U31A Molded Case Circuit Breaker 600V 1200A

(No reviews yet) Write a Review
SKU:
PGF36120U31A
UPC:
785901618744
Condition:
New
Circularity Profile:
ENVEOLI1407012EN
Terminal Identifier:
AL1200P25K
Depth:
8.05 in
Height:
16.16 in
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Range:
PowerPact
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Continuous Current Rating:
0.8
Circuit Breaker Application:
HACR rated
Mounting Mode:
unit mount busbar)
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Width:
8.27 in
Tightening Torque:
50-50 N.m 95-240 mm² (4 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
Trip Unit Technology:
electronic, standard, MicroLogic 3.0, LI
Quality Labels:
CE
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Long Time Pick-Up Adjustment Range:
0.4...1 x Ir
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Ip Degree Of Protection:
front cover IP40
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Network Frequency:
50/60 Hz
Sustainable Offer Status:
Green Premium product
Product Name:
PowerPact P
Electrical Connection:
busbar connection, line || busbar connection, load
[Ics] Rated Service Breaking Capacity:
25 kA 240 V AC 50/60 Hz IEC 60947-2 || 20 kA 380/415 V AC 50/60 Hz IEC 60947-2
Control Type:
toggle
Trip Unit Name:
MicroLogic 3.0
Product Certifications:
UL || CSA || NOM
Mercury Free:
Yes
Product Or Component Type:
circuit breaker
Quantity Per Set:
1
Breaking Capacity Code:
G
Mounting Support:
busbar
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Ambient Air Temperature For Operation:
-2-70 °C
Awg Gauge:
4 x AWG 3/0...500 kcmil aluminium/copper
Rohs Exemption Information:
Yes
Wire Stripping Length:
30 mm
Poles Description:
3P
Device Application:
distribution
Net Weight:
32 lb(US)
Local Signalling:
overload 1 trip indicator green) || 1 trip indicator green)
Ambient Air Temperature For Storage:
-50-85 °C
Pvc Free:
Yes
Eu Rohs Directive:
Compliant
Pollution Degree:
3 IEC 60947-1
Environmental Disclosure:
ENVPEP1407012EN
Breaking Capacity:
AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 35 kA 480 V AC 50/60 Hz UL 489 || AIR 18 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2
Line Rated Current:
1200-1200 A
Warranty:
18 months
$29,754.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Standard with a 3.0 trip unit and an LI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has a busbar connection. This PowerPacT P, 1200A, 3 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose