Schneider Electric

Schneider Electric PGL36100CU31A Molded Case Circuit Breaker 600V 1000A

(No reviews yet) Write a Review
SKU:
PGL36100CU31A
UPC:
7.85902E+11
Condition:
New
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Control Type:
toggle
Poles Description:
3P
Circuit Breaker Application:
HACR rated
Breaking Capacity Code:
G
Circularity Profile:
ENVEOLI2206033EN
Sustainable Offer Status:
Green Premium product
Quality Labels:
CE
Range:
PowerPact
Pollution Degree:
3 IEC 60947-1
Height:
16.16 in
Awg Gauge:
4 x AWG 3/0...500 kcmil aluminium/copper
Mercury Free:
Yes
Trip Unit Name:
MicroLogic 3.0
Depth:
8.05 in
Continuous Current Rating:
1
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Terminal Identifier:
AL1200P25K
Tightening Torque:
50-50 N.m 95-240 mm² (4 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
Product Certifications:
UL || CSA || NOM
Ambient Air Temperature For Operation:
-2-70 °C
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Long Time Pick-Up Adjustment Range:
0.4...1 x Ir
Warranty:
18 months
Device Application:
distribution
Wire Stripping Length:
30 mm
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Network Frequency:
50/60 Hz
Breaking Capacity:
AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 35 kA 480 V AC 50/60 Hz UL 489 || AIR 18 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2
Ip Degree Of Protection:
front cover IP40
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Product Or Component Type:
circuit breaker
Quantity Per Set:
1
[Ics] Rated Service Breaking Capacity:
25 kA 240 V AC 50/60 Hz IEC 60947-2 || 20 kA 380/415 V AC 50/60 Hz IEC 60947-2
Width:
8.27 in
Product Name:
PowerPact P
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Line Rated Current:
1000-1000 A
Ambient Air Temperature For Storage:
-50-85 °C
Electrical Connection:
lugs, load || lugs, line
Eu Rohs Directive:
Compliant with Exemptions
Net Weight:
32 lb(US)
Rohs Exemption Information:
Yes
Pvc Free:
Yes
Trip Unit Technology:
electronic, standard, MicroLogic 3.0, LI
Local Signalling:
1 trip indicator green)
Environmental Disclosure:
ENVPEP2206033EN
Brochure:
View
Catalog:
View
Datasheet:
View
$30,239.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Standard with a 3.0 trip unit and an LI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has lugs on both the line and load sides. This PowerPacT P, 1000A, 3 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker has a continuous current rating of 100%. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.