Device Application:
distribution
Breaking Capacity Code:
G
Breaking Capacity:
AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 35 kA 480 V AC 50/60 Hz UL 489 || AIR 18 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2
Ambient Air Temperature For Storage:
-50-85 °C
Pvc Free:
Yes
Mercury Free:
Yes
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Awg Gauge:
4 x AWG 3/0...500 kcmil aluminium/copper
Continuous Current Rating:
0.8
Width:
8.27 in
Trip Unit Name:
MicroLogic 6.0 P
Control Type:
toggle
Warranty:
18 months
Trip Unit Technology:
electronic, power, MicroLogic 6.0 P, LSI
Product Or Component Type:
circuit breaker
Line Rated Current:
1000-1000 A
Product Name:
PowerPact P
Quality Labels:
CE
Rohs Exemption Information:
Yes
Ambient Air Temperature For Operation:
-2-70 °C
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Environmental Disclosure:
ENVPEP2206033EN
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Accessory / Separate Part Type:
Modbus connecting cable
Range:
PowerPact
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Long Time Pick-Up Adjustment Range:
0.4...1 x Ir
Tightening Torque:
50-50 N.m 95-240 mm² (4 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
[Ics] Rated Service Breaking Capacity:
25 kA 240 V AC 50/60 Hz IEC 60947-2 || 20 kA 380/415 V AC 50/60 Hz IEC 60947-2
Eu Rohs Directive:
Compliant with Exemptions
Quantity Per Set:
1
Height:
16.16 in
Circuit Breaker Application:
HACR rated
Pollution Degree:
3 IEC 60947-1
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Wire Stripping Length:
30 mm
Communication Interface:
Modbus
Product Certifications:
UL || CSA || NOM
Local Signalling:
1 trip indicator green)
Sustainable Offer Status:
Green Premium product
Network Frequency:
50/60 Hz
Circularity Profile:
ENVEOLI2206033EN
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Depth:
8.05 in
Net Weight:
32 lb(US)
Electrical Connection:
lugs, load || lugs, line
Poles Description:
3P
Ip Degree Of Protection:
front cover IP40
Terminal Identifier:
AL1200P25K
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Brochure:
View
Catalog:
View
Datasheet:
View
$27,680.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Power with a 6.0P trip unit and an LSIG function with Modbus communications. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has lugs on both the line and load sides. This PowerPacT P, 1000A, 3 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.