Schneider Electric PGL36120 Molded Case Circuit Breaker 600V 1200A

(No reviews yet) Write a Review
SKU:
PGL36120
UPC:
785901446453
Condition:
New
Poles Description:
3P
Breaking Capacity:
AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 35 kA 480 V AC 50/60 Hz UL 489 || AIR 18 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2
Quantity Per Set:
1
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Height:
16.16 in
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Warranty:
18 months
Quality Labels:
CE
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Ambient Air Temperature For Operation:
-2-70 °C
Width:
8.27 in
Product Certifications:
UL || CSA || NOM
Local Signalling:
1 trip indicator green)
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Ip Degree Of Protection:
front cover IP40
Net Weight:
32 lb(US)
Ambient Air Temperature For Storage:
-50-85 °C
Terminal Identifier:
AL1200P25K
Device Application:
distribution
Environmental Disclosure:
ENVPEP2206033EN
Product Name:
PowerPact P
Range:
PowerPact
Breaking Capacity Code:
G
Network Frequency:
50/60 Hz
Pollution Degree:
3 IEC 60947-1
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Long Time Pick-Up Adjustment Range:
1 In
Circuit Breaker Application:
HACR rated
Rohs Exemption Information:
Yes
Electrical Connection:
lugs, load || lugs, line
Circularity Profile:
ENVEOLI2206033EN
Trip Unit Technology:
electronic, basic, ET 1.0I, I
Sustainable Offer Status:
Green Premium product
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Depth:
8.05 in
Trip Unit Name:
ET 1.0I
Mercury Free:
Yes
Pvc Free:
Yes
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Wire Stripping Length:
30 mm
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Continuous Current Rating:
0.8
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Awg Gauge:
4 x AWG 3/0...500 kcmil aluminium/copper
[Ics] Rated Service Breaking Capacity:
25 kA 240 V AC 50/60 Hz IEC 60947-2 || 20 kA 380/415 V AC 50/60 Hz IEC 60947-2
Eu Rohs Directive:
Compliant with Exemptions
Tightening Torque:
50-50 N.m 95-240 mm² (4 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
Line Rated Current:
1200-1200 A
Product Or Component Type:
circuit breaker
Control Type:
toggle
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric PGL36120 Molded Case Circuit Breaker 600V 1200A
  • Schneider Electric PGL36120 Molded Case Circuit Breaker 600V 1200A
  • Schneider Electric PGL36120 Molded Case Circuit Breaker 600V 1200A
$19,049.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has an electronic trip unit, ET 1.0I. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has lugs on both the line and load sides. This PowerPacT P, 1200A, 3 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose