- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz UL 489
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Mercury Free:
- Yes
- Ambient Air Temperature For Operation:
- -2-70 °C
- Electrical Connection:
- I-Line connection, line || lugs, load
- [Ics] Rated Service Breaking Capacity:
- 35 kA 240 V AC 50/60 Hz IEC 60947-2 || 25 kA 380/415 V AC 50/60 Hz IEC 60947-2
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Network Frequency:
- 50/60 Hz
- Net Weight:
- 32 lb(US)
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Circularity Profile:
- ENVEOLI1407012EN
- Line Rated Current:
- 800-800 A
- Device Application:
- distribution
- Poles Description:
- 3P
- Ambient Air Temperature For Storage:
- -50-85 °C
- Awg Gauge:
- 3 x AWG 3/0...500 kcmil aluminium/copper
- Phase Connection:
- ABC
- Trip Unit Name:
- MicroLogic 6.0 A
- Wire Stripping Length:
- 25 mm
- Breaking Capacity Code:
- J
- Product Certifications:
- UL || CSA || NOM
- Environmental Disclosure:
- ENVPEP1407012EN
- Quantity Per Set:
- 1
- Ip Degree Of Protection:
- front cover IP40
- Pvc Free:
- Yes
- Continuous Current Rating:
- 0.8
- Breaking Capacity:
- AIR 100 kA 240 V AC 50/60 Hz UL 489 || AIR 65 kA 480 V AC 50/60 Hz UL 489 || AIR 25 kA 600 V AC 50/60 Hz UL 489 || Icu 65 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
- Circuit Breaker Application:
- HACR rated
- Height:
- 12.86 in
- Eu Rohs Directive:
- Compliant
- Rohs Exemption Information:
- Yes
- Mounting Support:
- bracket
- Terminal Identifier:
- AL800M23K
- Width:
- 8.27 in
- Product Or Component Type:
- circuit breaker
- Trip Unit Technology:
- electronic, ammeter, MicroLogic 6.0 A, LSIG
- Mounting Height:
- 9 in
- Quality Labels:
- CE
- Local Signalling:
- overload 1 1 LED amber) || 1 flag green) || trip causes 4 trip indicator red)
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Long Time Pick-Up Adjustment Range:
- 0.4...1 x Ir
- Pollution Degree:
- 3 IEC 60947-1
- Product Name:
- PowerPact P
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
- Range:
- PowerPact
- Depth:
- 8.05 in
- Tightening Torque:
- 50-50 N.m 95-240 mm² (3 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
- Warranty:
- 18 months
- Sustainable Offer Status:
- Green Premium product
- Control Type:
- toggle
- Mounting Mode:
- I-Line bracket)