Schneider Electric PJF36100U33A Molded Case Circuit Breaker 600V 1000A

(No reviews yet) Write a Review
SKU:
PJF36100U33A
UPC:
785901764816
Condition:
New
Electrical Connection:
busbar connection, line || busbar connection, load
Breaking Capacity:
AIR 100 kA 240 V AC 50/60 Hz UL 489 || AIR 65 kA 480 V AC 50/60 Hz UL 489 || AIR 25 kA 600 V AC 50/60 Hz UL 489 || Icu 65 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
Tightening Torque:
50-50 N.m 95-240 mm² (4 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
Continuous Current Rating:
0.8
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Long Time Pick-Up Adjustment Range:
0.4...1 x Ir
[Ics] Rated Service Breaking Capacity:
35 kA 240 V AC 50/60 Hz IEC 60947-2 || 25 kA 380/415 V AC 50/60 Hz IEC 60947-2
Warranty:
18 months
Wire Stripping Length:
30 mm
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Ambient Air Temperature For Storage:
-50-85 °C
Product Or Component Type:
circuit breaker
Product Certifications:
UL || CSA || NOM
Terminal Identifier:
AL1200P25K
Control Type:
toggle
Pvc Free:
Yes
Trip Unit Name:
MicroLogic 5.0
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Local Signalling:
overload 1 trip indicator green) || 1 trip indicator green)
Trip Unit Technology:
electronic, standard, MicroLogic 5.0, LSI
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Depth:
8.05 in
Awg Gauge:
4 x AWG 3/0...500 kcmil aluminium/copper
Circularity Profile:
ENVEOLI2206033EN
Height:
16.16 in
Circuit Breaker Application:
HACR rated
Mounting Support:
busbar
Line Rated Current:
1000-1000 A
Rohs Exemption Information:
Yes
Ambient Air Temperature For Operation:
-2-70 °C
Mounting Mode:
unit mount busbar)
Quality Labels:
CE
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Network Frequency:
50/60 Hz
Pollution Degree:
3 IEC 60947-1
Quantity Per Set:
1
Eu Rohs Directive:
Compliant with Exemptions
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Width:
8.27 in
Ip Degree Of Protection:
front cover IP40
Environmental Disclosure:
ENVPEP2206033EN
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Mercury Free:
Yes
Sustainable Offer Status:
Green Premium product
Poles Description:
3P
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Range:
PowerPact
Breaking Capacity Code:
J
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Device Application:
distribution
Product Name:
PowerPact P
Net Weight:
32 lb(US)
$32,067.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Standard with a 5.0 trip unit and an LSI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has a busbar connection. This PowerPacT P, 1000A, 3 pole, circuit breaker has an interrupting rating of 25kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose