Schneider Electric PJL36040U31A Molded Case Circuit Breaker 600V 400A

(No reviews yet) Write a Review
SKU:
PJL36040U31A
UPC:
785901947455
Condition:
New
Poles Description:
3P
Trip Unit Technology:
electronic, standard, MicroLogic 3.0, LI
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Terminal Identifier:
AL800M23K
Quality Labels:
CE
Pvc Free:
Yes
Product Or Component Type:
circuit breaker
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Circuit Breaker Application:
HACR rated
Environmental Disclosure:
ENVPEP2206033EN
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Range:
PowerPact
Continuous Current Rating:
0.8
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
[Ics] Rated Service Breaking Capacity:
35 kA 240 V AC 50/60 Hz IEC 60947-2 || 25 kA 380/415 V AC 50/60 Hz IEC 60947-2
Warranty:
18 months
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Rohs Exemption Information:
Yes
Breaking Capacity Code:
J
Mercury Free:
Yes
Tightening Torque:
50-50 N.m 95-240 mm² (3 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
Height:
12.86 in
Product Name:
PowerPact P
Sustainable Offer Status:
Green Premium product
Control Type:
toggle
Device Application:
distribution
Depth:
8.05 in
Breaking Capacity:
AIR 100 kA 240 V AC 50/60 Hz UL 489 || AIR 65 kA 480 V AC 50/60 Hz UL 489 || AIR 25 kA 600 V AC 50/60 Hz UL 489 || Icu 65 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
Eu Rohs Directive:
Compliant with Exemptions
Width:
8.27 in
Line Rated Current:
400-400 A
Mounting Support:
lug
Network Frequency:
50/60 Hz
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Ambient Air Temperature For Operation:
-2-70 °C
Ambient Air Temperature For Storage:
-50-85 °C
Quantity Per Set:
1
Wire Stripping Length:
25 mm
Net Weight:
32 lb(US)
Local Signalling:
overload 1 trip indicator green) || 1 trip indicator green)
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Mounting Mode:
unit mount lug)
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Circularity Profile:
ENVEOLI2206033EN
Pollution Degree:
3 IEC 60947-1
Awg Gauge:
3 x AWG 3/0...500 kcmil aluminium/copper
Ip Degree Of Protection:
front cover IP40
Long Time Pick-Up Adjustment Range:
0.4...1 x Ir
Trip Unit Name:
MicroLogic 3.0
Electrical Connection:
lugs, line || lugs, load
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Product Certifications:
UL || CSA || NOM
Brochure:
View
Catalog:
View
Datasheet:
View
$15,570.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Standard with a 3.0 trip unit and an LI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has lugs on both the line and load sides. This PowerPacT P, 400A, 3 pole, circuit breaker has an interrupting rating of 25kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.