Schneider Electric PJL36080 Molded Case Circuit Breaker 600V 800A

(No reviews yet) Write a Review
SKU:
PJL36080
UPC:
7.85902E+11
Condition:
New
Continuous Current Rating:
0.8
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Pvc Free:
Yes
[Ics] Rated Service Breaking Capacity:
35 kA 240 V AC 50/60 Hz IEC 60947-2 || 25 kA 380/415 V AC 50/60 Hz IEC 60947-2
Trip Unit Name:
ET 1.0I
Ambient Air Temperature For Storage:
-50-85 °C
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Awg Gauge:
3 x AWG 3/0...500 kcmil aluminium/copper
Rohs Exemption Information:
Yes
Product Certifications:
UL || CSA || NOM
Circularity Profile:
ENVEOLI2206033EN
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Range:
PowerPact
Tightening Torque:
50-50 N.m 95-240 mm² (3 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
Mercury Free:
Yes
Long Time Pick-Up Adjustment Range:
1 In
Mounting Support:
lug
Device Application:
distribution
Line Rated Current:
800-800 A
Ip Degree Of Protection:
front cover IP40
Ambient Air Temperature For Operation:
-2-70 °C
Control Type:
toggle
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Environmental Disclosure:
ENVPEP2206033EN
Width:
8.27 in
Breaking Capacity Code:
J
Warranty:
18 months
Pollution Degree:
3 IEC 60947-1
Mounting Mode:
unit mount lug)
Circuit Breaker Application:
HACR rated
Network Frequency:
50/60 Hz
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Net Weight:
32 lb(US)
Wire Stripping Length:
25 mm
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Poles Description:
3P
Sustainable Offer Status:
Green Premium product
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Terminal Identifier:
AL800M23K
Quality Labels:
CE
Product Name:
PowerPact P
Trip Unit Technology:
electronic, basic, ET 1.0I, I
Height:
12.86 in
Local Signalling:
1 trip indicator green)
Depth:
8.05 in
Breaking Capacity:
AIR 100 kA 240 V AC 50/60 Hz UL 489 || AIR 65 kA 480 V AC 50/60 Hz UL 489 || AIR 25 kA 600 V AC 50/60 Hz UL 489 || Icu 65 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Quantity Per Set:
1
Electrical Connection:
lugs, line || lugs, load
Eu Rohs Directive:
Compliant with Exemptions
Product Or Component Type:
circuit breaker
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric PJL36080 Molded Case Circuit Breaker 600V 800A
  • Schneider Electric PJL36080 Molded Case Circuit Breaker 600V 800A
$14,783.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has an electronic trip unit, ET 1.0I. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has lugs on both the line and load sides. This PowerPacT P, 800A, 3 pole, circuit breaker has an interrupting rating of 25kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose