Schneider Electric PJL36100 Molded Case Circuit Breaker 600V 1000A

(No reviews yet) Write a Review
SKU:
PJL36100
UPC:
785901892939
Condition:
New
Trip Unit Technology:
electronic, basic, ET 1.0I, I
Continuous Current Rating:
0.8
Circularity Profile:
ENVEOLI2206033EN
Local Signalling:
1 trip indicator green)
Sustainable Offer Status:
Green Premium product
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Circuit Breaker Application:
HACR rated
Ambient Air Temperature For Storage:
-50-85 °C
Height:
16.16 in
Product Certifications:
UL || CSA || NOM
Terminal Identifier:
AL1200P25K
Tightening Torque:
50-50 N.m 95-240 mm² (4 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
Breaking Capacity Code:
J
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Device Application:
distribution
Eu Rohs Directive:
Compliant with Exemptions
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Long Time Pick-Up Adjustment Range:
1 In
Quality Labels:
CE
Warranty:
18 months
Pollution Degree:
3 IEC 60947-1
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Awg Gauge:
4 x AWG 3/0...500 kcmil aluminium/copper
Net Weight:
32 lb(US)
Pvc Free:
Yes
Ip Degree Of Protection:
front cover IP40
Line Rated Current:
1000-1000 A
Breaking Capacity:
AIR 100 kA 240 V AC 50/60 Hz UL 489 || AIR 65 kA 480 V AC 50/60 Hz UL 489 || AIR 25 kA 600 V AC 50/60 Hz UL 489 || Icu 65 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
Environmental Disclosure:
ENVPEP2206033EN
Depth:
8.05 in
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Ambient Air Temperature For Operation:
-2-70 °C
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Wire Stripping Length:
30 mm
Poles Description:
3P
Network Frequency:
50/60 Hz
Product Or Component Type:
circuit breaker
Quantity Per Set:
1
Mounting Support:
lug
Electrical Connection:
lugs, line || lugs, load
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
[Ics] Rated Service Breaking Capacity:
35 kA 240 V AC 50/60 Hz IEC 60947-2 || 25 kA 380/415 V AC 50/60 Hz IEC 60947-2
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Mounting Mode:
unit mount lug)
Rohs Exemption Information:
Yes
Product Name:
PowerPact P
Control Type:
toggle
Width:
8.27 in
Trip Unit Name:
ET 1.0I
Mercury Free:
Yes
Range:
PowerPact
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric PJL36100 Molded Case Circuit Breaker 600V 1000A
  • Schneider Electric PJL36100 Molded Case Circuit Breaker 600V 1000A
  • Schneider Electric PJL36100 Molded Case Circuit Breaker 600V 1000A
$20,250.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has an electronic trip unit, ET 1.0I. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has lugs on both the line and load sides. This PowerPacT P, 1000A, 3 pole, circuit breaker has an interrupting rating of 25kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose