Schneider Electric PLA34080 Molded Case Circuit Breaker 480V 800A

(No reviews yet) Write a Review
SKU:
PLA34080
UPC:
785901493396
Condition:
New
Wire Stripping Length:
25 mm
Product Certifications:
UL || CSA || NOM
Quantity Per Set:
1
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Circuit Breaker Application:
HACR rated
Mounting Mode:
I-Line bracket)
[Ue] Rated Operational Voltage:
480 V AC 50/60 Hz UL 489
Control Type:
toggle
Net Weight:
32 lb(US)
Height:
12.86 in
Quality Labels:
CE
Line Rated Current:
800-800 A
Width:
8.27 in
Trip Unit Technology:
electronic, basic, ET 1.0I, I
Mounting Height:
9 in
Mercury Free:
Yes
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Continuous Current Rating:
0.8
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Long Time Pick-Up Adjustment Range:
1 In
Rohs Exemption Information:
Yes
Depth:
8.05 in
Local Signalling:
1 trip indicator green)
Network Frequency:
50/60 Hz
Breaking Capacity:
AIR 125 kA 240 V AC 50/60 Hz UL 489 || AIR 100 kA 480 V AC 50/60 Hz UL 489 || AIR 25 kA 600 V AC 50/60 Hz UL 489 || Icu 125 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 85 kA 380/415 V AC 50/60 Hz IEC 60947-2
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Breaking Capacity Code:
L
Terminal Identifier:
AL800M23K
Range:
PowerPact
Pollution Degree:
3 IEC 60947-1
Eu Rohs Directive:
Compliant with Exemptions
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Ip Degree Of Protection:
front cover IP40
Device Application:
distribution
Warranty:
18 months
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Electrical Connection:
I-Line connection, line || lugs, load
Ambient Air Temperature For Operation:
-2-70 °C
Awg Gauge:
3 x AWG 3/0...500 kcmil aluminium/copper
Circularity Profile:
ENVEOLI2206033EN
Phase Connection:
ABC
Ambient Air Temperature For Storage:
-50-85 °C
Pvc Free:
Yes
Poles Description:
3P
Product Or Component Type:
circuit breaker
Product Name:
PowerPact P
[Ics] Rated Service Breaking Capacity:
65 kA 240 V AC 50/60 Hz IEC 60947-2 || 45 kA 380/415 V AC 50/60 Hz IEC 60947-2
Environmental Disclosure:
ENVPEP2206033EN
Sustainable Offer Status:
Green Premium product
Trip Unit Name:
ET 1.0I
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Mounting Support:
bracket
Tightening Torque:
50-50 N.m 95-240 mm² (3 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric PLA34080 Molded Case Circuit Breaker 480V 800A
  • Schneider Electric PLA34080 Molded Case Circuit Breaker 480V 800A
  • Schneider Electric PLA34080 Molded Case Circuit Breaker 480V 800A
$16,359.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has an electronic trip unit, ET 1.0I. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT P, 800A, 3 pole, circuit breaker has an interrupting rating of 100kA at 480VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose