[Uimp] Rated Impulse Withstand Voltage:
5 kV 1.2/50 µs
Ambient Air Temperature For Storage:
-30-60 °C
Power Consumption In Va:
0-3 VA 240 V AC
Tightening Torque:
0.6-1 N.m IEC 60947-1
[Us] Rated Supply Voltage:
24...240 V AC 50/60 Hz
Safety Reliability Data:
MTTFd = 353.8 years || B10d = 320000
Mounting Position:
any position in relation to normal vertical mounting plane
Time Delay Type:
off-delay
Creepage Distance:
4 kV/3 IEC 60664-1
Temperature Drift:
+/- 0.05 %/°C
Minimum Switching Current:
10 mA
Product Or Component Type:
single function relay
Setting Accuracy Of Time Delay:
+/- 10 % of full scale 25 °C IEC 61812-1
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Net Weight:
0.068 kg
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
Electrical Durability:
100000000 cycles
Time Delay Type:
C
Mercury Free:
Yes
Repeat Accuracy:
+/- 0.5 % IEC 61812-1
Width:
17.5 mm
Dielectric Strength:
2.5 kV 1 mA/1 minute 50 Hz IEC 61812-1
Relative Humidity:
93-93 % without condensation IEC 60068-2-30
Range Of Product:
Harmony Timer Relays
Sustainable Offer Status:
Green Premium product
Maximum Switching Voltage:
250 V AC
Component Name:
RE17L
Mounting Support:
35 mm DIN rail conforming to IEC 60715
Maximum Leakage Current:
5 mA
Voltage Drift:
+/- 0.2 %/V
Reset Time:
350 ms on de-energisation typical
Discrete Output Type:
solid state
Impulse Duration:
0.05 s typical
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Circularity Profile:
ENVEOLI121113EN
Immunity To Microbreaks:
20 ms
Time Delay Range:
10...100 h || 6...60 s || 6...60 min || 1...10 h || 1...10 s || 1...10 min || 0.1...1 s
Electromagnetic Compatibility:
electrostatic discharge immunity test 6 kV in contact) level 3 IEC 61000-4-2 || electrostatic discharge immunity test 8 kV in air) level 3 IEC 61000-4-2 || susceptibility to electromagnetic fields 10 V/m 80 MHz to 1 GHz) level 3 IEC 61000-4-3 || elec
Supply Frequency:
50...60 Hz +/- 5 %
Derating Factor:
5 mA/°C
Compatibility Code:
RE17
Voltage Range:
0.85...1.1 Us
Maximum Delay Response:
100 ms
Operating Rate In Hz:
10 Hz
Maximum Output Current:
20 A
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
On-Load Factor:
1
Ambient Air Temperature For Operation:
-20-60 °C
Rohs Exemption Information:
Yes
Product Certifications:
CSA || GL || cULus
Ip Degree Of Protection:
IP20 IEC 60529 terminal block) || IP40 IEC 60529 housing) || IP50 IEC 60529 front panel)
Standards:
2004/108/EC || IEC 61000-6-3 || 2006/95/EC || IEC 61000-6-2 || IEC 61812-1 || IEC 61000-6-4 || IEC 61000-6-1
Breaking Capacity:
0.5 A AC UL || 0.7 A AC 20 °C
Control Type:
selector switch front panel
Insulation Resistance:
100 MOhm 500 V DC IEC 60664-1
Input Voltage:
7 V
Functionality:
off-delay timing
Marking:
CE
Nominal Output Current:
0.7 A
Housing Material:
self-extinguishing
Environmental Disclosure:
ENVPEP121117EN
Vibration Resistance:
20 m/s² 10-150 Hz)IEC 60068-2-6
Maximum Voltage Drop:
<4 V 3-wire || <8 V 2-wire
  • Schneider Electric RE17LCBM Off Delay Timer 24 240Vac
  • Schneider Electric RE17LCBM Off Delay Timer 24 240Vac
  • Schneider Electric RE17LCBM Off Delay Timer 24 240Vac
$52.00

Description

This Harmony RE17L timing relay can be set between 0.1 seconds and 100 hours, has an output rating of 0.7A, is 17.5mm wide and can be supplied with 24V to 240V AC. It also has a solid state output. It has one of market slimmest form-factors, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 1-pole DIN device. It also offers a sealable cover, simple and precise settings with rotary trimmers. Single function timer for a simple integration in hard-wired logic schematics, ideal for refurbishment of old installations without using a PLC. 0 0 0 0 0 0 0 0 0 0 0 0 0 0