Schneider Electric RE22R1AMR On Delay Timer
Schneider Electric
$59.76
This Harmony RE22 modular dual function timer can be set between 0.05 seconds and 300 hours, has an output rating of 8 amperes and it is 22.5 millimeters wide. It provides function A and function Aw and it is mountable on DIN rail. This modular dual function timing relay is ideal for providing timing control in automation systems such as automatic door opening, alarm, lighting in toilets and car park barriers. It has one of market slimmest form-factors with 22.5mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 2-pole DIN device. It also offers a sealable cover, simple and precise settings with rotary trimmers. Selectable timing range offers a one stop solution for your power management system. Dual function timer for a simple integration in hard-wired logic schematics, ideal for refurbishment of old installations without using a PLC. 0 0 0 0 0 0 0 0 0 0 0 0
- Range Of Product:
- Harmony Timer Relays
- Repeat Accuracy:
- +/- 0.5 % IEC 61812-1
- Connections - Terminals:
- screw terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end || screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end || screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end |
- Maximum Switching Current:
- 0.333333333333333
- Nominal Output Current:
- 0.333333333333333
- Circularity Profile:
- ENVEOLI1401008EN
- Relative Humidity:
- 95-95 % 25-55 °C
- Product Certifications:
- CE || UL || GL || CCC || EAC || RCM || CSA
- Discrete Output Type:
- relay
- Input Voltage:
- <= 2.4 V
- Mechanical Durability:
- 10000000 cycles
- Housing Material:
- self-extinguishing
- Ambient Air Temperature For Storage:
- -40-70 °C
- Directives:
- 2006/95/EC - low voltage directive || 2004/108/EC - electromagnetic compatibility
- Electrical Durability:
- 100000 cycles, 8 A at 250 V, AC-1 || 100000 cycles, 2 A at 24 V, DC-1
- Product Or Component Type:
- dual function relay
- Rohs Exemption Information:
- Yes
- Shock Resistance:
- 15 gn not operating 11 ms IEC 60068-2-27 || 5 gn in operation 11 ms IEC 60068-2-27
- Standards:
- UL 508 || IEC 61812-1
- Ambient Air Temperature For Operation:
- -20-60 °C
- Ip Degree Of Protection:
- housing IP40 IEC 60529 || front face IP50 IEC 60529 || terminals IP20 IEC 60529
- Supply Frequency:
- 50...60 Hz +/- 5 %
- Dielectric Strength:
- 2.5 kV 1 mA/1 minute 50 Hz between relay output and power supply basic insulation IEC 61812-1
- Switching Capacity In Va:
- 2000 VA
- Environmental Disclosure:
- ENVPEP1401008EN
- China Rohs Regulation:
- X
- Mercury Free:
- Yes
- Temperature Drift:
- +/- 0.05 %/°C
- [Us] Rated Supply Voltage:
- 24...240 V AC/DC 50/60 Hz
- Minimum Pulse Duration:
- 100 ms with load in parallel || 30 ms
- Time Delay Type:
- power on-delay
- Time Delay Range:
- 3...30 s || 30...300 s || 10...100 s || 0.05...1 s || 1...10 s || 30...300 h || 30...300 min || 0.3...3 s || 3...30 h || 3...30 min
- Electromagnetic Compatibility:
- fast transients immunity test - test level: 1 kV level 3 (capacitive connecting clip) conforming to IEC 61000-4-4 || surge immunity test - test level: 1 kV level 3 (differential mode) conforming to IEC 61000-4-5 || surge immunity test - test level: 2
- Safety Reliability Data:
- MTTFd = 308.2 years || B10d = 280000
- Insulation Resistance:
- 100 MOhm 500 V DC IEC 60664-1
- Maximum Switching Voltage:
- 250 V AC
- Net Weight:
- 0.1 kg
- Setting Accuracy Of Time Delay:
- +/- 10 % of full scale 25 °C IEC 61812-1
- Power Consumption In Va:
- 3-3 VA 240 V AC
- Width:
- 22.5 mm
- Maximum Delay Response:
- 100 ms
- Control Type:
- rotary knob || diagnostic button
- Eu Rohs Directive:
- Pro-active compliance (Product out of EU RoHS legal scope)
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Vibration Resistance:
- 20 m/s² 10-150 Hz)IEC 60068-2-6
- Mounting Position:
- any position
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- [Uimp] Rated Impulse Withstand Voltage:
- 5 kV 1.2-50 µs IEC 60664-1
- Status Led:
- Green LED backlight steady)dial pointer indication || Yellow LED steady)output relay energised || Yellow LED fast flashing)timing in progress and output relay de-energised || Yellow LED slow flashing)timing in progress and output relay energised
- Contacts Type And Composition:
- 1 C/O timed contact, cadmium free
- Minimum Switching Current:
- 10 mA 5 V DC
- Pollution Degree:
- 3 IEC 60664-1
- Tightening Torque:
- 0.6-1 N.m IEC 60947-1
- Overvoltage Category:
- III IEC 60664-1
- Sustainable Offer Status:
- Green Premium product
- Creepage Distance:
- 4 kV/3 IEC 60664-1
- Voltage Drift:
- +/- 0.2 %/V
- Voltage Range:
- 0.85...1.1 Us
- Power Consumption In W:
- 1.5 W 240 V DC
- Mounting Support:
- 35 mm DIN rail conforming to IEC 60715
- Reset Time:
- 120 ms on de-energisation
- Immunity To Microbreaks:
- 10 ms
- Device Short Name:
- RE22
- Catalog:
- View
- Datasheet:
- View