Schneider Electric RE22R2HMR Pulse-On Energisation Timer Relay

(No reviews yet) Write a Review
SKU:
RE22R2HMR
UPC:
3606480792489
Condition:
New
Standards:
IEC 61812-1 || UL 508
Power Consumption In W:
1.5 W 240 V DC
Mounting Position:
any position
Mercury Free:
Yes
Contacts Type And Composition:
1 C/O timed contact, cadmium free || 1 C/O timed or instantaneous contact, cadmium free
Connections - Terminals:
screw terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end || screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end || screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end || s
Maximum Switching Voltage:
250 V AC
Device Short Name:
RE22
Environmental Disclosure:
ENVPEP1401008EN
Product Or Component Type:
dual function relay
[Uimp] Rated Impulse Withstand Voltage:
5 kV 1.2-50 µs IEC 60664-1
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Nominal Output Current:
0.333333333333333
Product Certifications:
RCM || CSA || CE || EAC || UL || CCC || GL
Ip Degree Of Protection:
housing IP40 IEC 60529 || terminals IP20 IEC 60529 || front panel IP50 IEC 60529
Housing Material:
self-extinguishing
Minimum Switching Current:
10 mA 5 V DC
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Switching Capacity In Va:
2000 VA
Rohs Exemption Information:
Yes
Time Delay Type:
interval
Net Weight:
0.105 kg
Relative Humidity:
95-95 % 25-55 °C
Power Consumption In Va:
3-3 VA 240 V AC
Voltage Drift:
+/- 0.2 %/V
Status Led:
Green LED backlight steady)dial pointer indication || Yellow LED steady)output relay energised || Yellow LED fast flashing)timing in progress and output relay de-energised || Yellow LED slow flashing)timing in progress and output relay energised
Sustainable Offer Status:
Green Premium product
Ambient Air Temperature For Operation:
-20-60 °C
Control Type:
rotary knob || diagnostic button || potentiometer external
Ambient Air Temperature For Storage:
-40-70 °C
Repeat Accuracy:
+/- 0.5 % IEC 61812-1
Time Delay Range:
1...10 s || 3...30 h || 10...100 s || 30...300 s || 0.05...1 s || 3...30 min || 0.3...3 s || 3...30 s || 30...300 min || 30...300 h
Maximum Switching Current:
0.333333333333333
Discrete Output Type:
relay
Width:
22.5 mm
Dielectric Strength:
2.5 kV 1 mA/1 minute 50 Hz between relay output and power supply basic insulation IEC 61812-1
Directives:
2006/95/EC - low voltage directive || 2004/108/EC - electromagnetic compatibility
Electrical Durability:
100000 cycles, 8 A at 250 V, AC-1 || 100000 cycles, 2 A at 24 V, DC-1
Maximum Delay Response:
100 ms
Mounting Support:
35 mm DIN rail conforming to IEC 60715
Insulation Resistance:
100 MOhm 500 V DC IEC 60664-1
Input Voltage:
<= 2.4 V
Mechanical Durability:
10000000 cycles
Supply Frequency:
50...60 Hz +/- 5 %
Reset Time:
120 ms on de-energisation
Setting Accuracy Of Time Delay:
+/- 10 % of full scale 25 °C IEC 61812-1
Electromagnetic Compatibility:
fast transients immunity test - test level: 1 kV level 3 (capacitive connecting clip) conforming to IEC 61000-4-4 || surge immunity test - test level: 1 kV level 3 (differential mode) conforming to IEC 61000-4-5 || surge immunity test - test level: 2
Creepage Distance:
4 kV/3 IEC 60664-1
Voltage Range:
0.85...1.1 Us
Temperature Drift:
+/- 0.05 %/°C
Immunity To Microbreaks:
10 ms
China Rohs Regulation:
X
Safety Reliability Data:
B10d = 200000 || MTTFd = 216.8 years
Pollution Degree:
3 IEC 60664-1
Shock Resistance:
15 gn not operating 11 ms IEC 60068-2-27 || 5 gn in operation 11 ms IEC 60068-2-27
Overvoltage Category:
III IEC 60664-1
Vibration Resistance:
20 m/s² 10-150 Hz)IEC 60068-2-6
[Us] Rated Supply Voltage:
24...240 V AC/DC 50/60 Hz
Tightening Torque:
0.6-1 N.m IEC 60947-1
Circularity Profile:
ENVEOLI1401008EN
Minimum Pulse Duration:
100 ms with load in parallel || 30 ms
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Range Of Product:
Harmony Timer Relays
  • Schneider Electric RE22R2HMR Pulse-On Energisation Timer Relay
  • Schneider Electric RE22R2HMR Pulse-On Energisation Timer Relay
  • Schneider Electric RE22R2HMR Pulse-On Energisation Timer Relay
$76.13

Description

This Harmony RE22 modular dual function timer can be set between 1 seconds and 300 hours. It provides function H and function Hw and it is mountable on DIN rail. This modular dual function timing relay is ideal for providing timing control in automation systems such as automatic door opening, alarm, lighting in toilets and car park barriers. It has one of market slimmest form-factors with 22.5mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 2-pole DIN device. It also offers a sealable cover, simple and precise settings with rotary trimmers. Selectable timing range offers a one stop solution for your power management system. Dual function timer for a simple integration in hard-wired logic schematics, ideal for refurbishment of old installations without using a PLC. 0 0 0 0 0 0 0 0 0 0 0 0
View AllClose