- Range:
- PowerPact
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
- Net Weight:
- 52 lb(US)
- Utilisation Category:
- category A
- Pollution Degree:
- 3 IEC 60947-1
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 voltage release MN or MX plug-in)
- Standards:
- UL || CSA || NEMA || NMX J-266 || IEC 60947-2
- Awg Gauge:
- AWG 3/0...750 kcmil aluminium/copper
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Trip Unit Name:
- MicroLogic 3.0
- Ambient Air Temperature For Storage:
- -50-85 °C
- Ambient Air Temperature For Operation:
- -25-70 °C
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz UL 489
- Width:
- 16.53 in
- Sustainable Offer Status:
- Green Premium product
- Environmental Disclosure:
- ENVPEP2206034EN
- Tightening Torque:
- 68-68 N.m 50-400 mm² (AWG 1/0...750 kcmil) || 68-68 N.m 50-150 mm² (2 x AWG 1/0...2 x 300 kcmil)
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Wire Stripping Length:
- 35 mm
- Electrical Connection:
- busbar connection, line || busbar connection, load
- Device Application:
- distribution
- Pvc Free:
- Yes
- Ip Degree Of Protection:
- IP40
- Line Rated Current:
- 1600-1600 A
- Mounting Mode:
- unit mount busbar)
- Circularity Profile:
- ENVEOLI2206034EN
- Depth:
- 14.49 in
- Breaking Capacity:
- AIR 100 kA 240 V AC 50/60 Hz UL 489 || AIR 65 kA 480 V AC 50/60 Hz UL 489 || AIR 25 kA 600 V AC 50/60 Hz UL 489 || Icu 65 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
- Mounting Support:
- busbar
- Local Signalling:
- alarm 1 LED yellow)long-time pick up)
- Suitability For Isolation:
- yes IEC 60947-2
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Quality Labels:
- CE
- Mercury Free:
- Yes
- Rohs Exemption Information:
- Yes
- Warranty:
- 18 months
- Circuit Breaker Application:
- HACR rated
- Trip Unit Technology:
- electronic, standard, MicroLogic 3.0, LI
- Product Or Component Type:
- circuit breaker
- Poles Description:
- 3P
- Height:
- 16.24 in
- [Ics] Rated Service Breaking Capacity:
- 35 kA 240 V AC 50/60 Hz IEC 60947-2 || 25 kA 380/415 V AC 50/60 Hz IEC 60947-2
- Product Certifications:
- UL || CSA || NOM
- Quantity Per Set:
- 1
- Terminal Identifier:
- AL2500RK
- Control Type:
- operating handle
- Breaking Capacity Code:
- J
- Continuous Current Rating:
- 1
- Network Frequency:
- 50/60 Hz
- Halogen Content Performance:
- Halogen free plastic parts product
- Eu Rohs Directive:
- Compliant with Exemptions
- Product Name:
- PowerPact R