- Environmental Disclosure:
- ENVPEP2206034EN
- Network Frequency:
- 50/60 Hz
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Trip Unit Technology:
- electronic, ammeter, MicroLogic 6.0 A, LSIG
- Width:
- 16.53 in
- Eu Rohs Directive:
- Compliant with Exemptions
- Wire Stripping Length:
- 35 mm
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Local Signalling:
- alarm 1 LED yellow)long-time pick up) || 1 LED red)long-time pick up) || trip causes 1 LED red) || 1 LED red)digital ammeter) || ground indicator 1 LED red) || phase-loading LED green)load balancing)
- Pollution Degree:
- 3 IEC 60947-1
- Net Weight:
- 52 lb(US)
- Height:
- 16.24 in
- Trip Unit Name:
- MicroLogic 6.0 A
- Device Application:
- distribution
- Pvc Free:
- Yes
- Halogen Content Performance:
- Halogen free plastic parts product
- Mercury Free:
- Yes
- Product Name:
- PowerPact R
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 voltage release MN or MX plug-in)
- Product Certifications:
- UL || CSA || NOM
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
- Utilisation Category:
- category A
- Continuous Current Rating:
- 0.8
- [Ics] Rated Service Breaking Capacity:
- 65 kA 240 V AC 50/60 Hz IEC 60947-2 || 55 kA 380/415 V AC 50/60 Hz IEC 60947-2
- Range:
- PowerPact
- Control Type:
- operating handle
- Quality Labels:
- CE
- Sustainable Offer Status:
- Green Premium product
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz UL 489
- Product Or Component Type:
- circuit breaker
- Ambient Air Temperature For Storage:
- -50-85 °C
- Rohs Exemption Information:
- Yes
- Tightening Torque:
- 68-68 N.m 50-400 mm² (AWG 1/0...750 kcmil) || 68-68 N.m 50-150 mm² (2 x AWG 1/0...2 x 300 kcmil)
- Breaking Capacity Code:
- K
- Breaking Capacity:
- AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 65 kA 480 V AC 50/60 Hz UL 489 || AIR 65 kA 600 V AC 50/60 Hz UL 489 || Icu 85 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 70 kA 380/415 V AC 50/60 Hz IEC 60947-2
- Warranty:
- 18 months
- Ambient Air Temperature For Operation:
- -25-70 °C
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Mounting Support:
- busbar
- Electrical Connection:
- busbar connection, line || busbar connection, load
- Ip Degree Of Protection:
- IP40
- Standards:
- UL || CSA || NEMA || NMX J-266 || IEC 60947-2
- Suitability For Isolation:
- yes IEC 60947-2
- Circularity Profile:
- ENVEOLI2206034EN
- Depth:
- 14.49 in
- Line Rated Current:
- 2000-2000 A
- Poles Description:
- 3P
- Awg Gauge:
- AWG 3/0...750 kcmil aluminium/copper
- Quantity Per Set:
- 1
- Terminal Identifier:
- AL2500RK
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Circuit Breaker Application:
- HACR rated
- Mounting Mode:
- unit mount busbar)