Schneider Electric RLA36120CU44A Molded Case Circuit Breaker 600V 1200A

(No reviews yet) Write a Review
SKU:
RLA36120CU44A
UPC:
785901234111
Condition:
New
Sustainable Offer Status:
Green Premium product
Device Application:
distribution
Standards:
UL || CSA || NEMA || NMX J-266 || IEC 60947-2
Utilisation Category:
category A
Ip Degree Of Protection:
IP40
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Trip Unit Name:
MicroLogic 6.0 A
Circularity Profile:
ENVEOLI2206034EN
Product Certifications:
UL || CSA || NOM
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Pollution Degree:
3 IEC 60947-1
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Quantity Per Set:
1
Electrical Connection:
I-Line connection, line || lugs, load
Breaking Capacity:
AIR 125 kA 240 V AC 50/60 Hz UL 489 || AIR 100 kA 480 V AC 50/60 Hz UL 489 || AIR 50 kA 600 V AC 50/60 Hz UL 489 || Icu 125 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 85 kA 380/415 V AC 50/60 Hz IEC 60947-2
Eu Rohs Directive:
Compliant with Exemptions
Control Type:
operating handle
Suitability For Isolation:
yes IEC 60947-2
Circuit Breaker Application:
HACR rated
Network Frequency:
50/60 Hz
Ambient Air Temperature For Operation:
-25-70 °C
Mounting Mode:
I-Line bracket)
Product Name:
PowerPact R
Warranty:
18 months
[Ics] Rated Service Breaking Capacity:
65 kA 240 V AC 50/60 Hz IEC 60947-2 || 45 kA 380/415 V AC 50/60 Hz IEC 60947-2
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Local Signalling:
alarm 1 LED yellow)long-time pick up) || 1 LED red)long-time pick up) || trip causes 1 LED red) || 1 LED red)digital ammeter) || ground indicator 1 LED red) || phase-loading LED green)load balancing)
Awg Gauge:
4 x AWG 3/0…600 kcmil aluminium/copper || 4 x AWG 3/0...500 kcmil copper
Pvc Free:
Yes
Wire Stripping Length:
30 mm
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Poles Description:
3P
Depth:
13.78 in
Ambient Air Temperature For Storage:
-50-85 °C
Line Rated Current:
1200-1200 A
Net Weight:
52 lb(US)
Terminal Identifier:
AL1200R53K
Tightening Torque:
28-28 N.m 95-240 mm² (4 x AWG 3/0…600 kcmil)
Rohs Exemption Information:
Yes
Mounting Support:
bracket
Continuous Current Rating:
1
Breaking Capacity Code:
L
Trip Unit Technology:
electronic, ammeter, MicroLogic 6.0 A, LSIG
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Product Or Component Type:
circuit breaker
Halogen Content Performance:
Halogen free plastic parts product
Environmental Disclosure:
ENVPEP2206034EN
Width:
14.96 in
Quality Labels:
CE
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 voltage release MN or MX plug-in)
Range:
PowerPact
Height:
13.38 in
Mercury Free:
Yes
$43,434.00

Description

PowerPacT R-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT R-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Ammeter with a 6.0A trip unit and an LSIG function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT R circuit breakers are available in 2, 3, and 4-pole unit mount and I-Line construction (I-Line construction is available for 1000A and 1200A rated circuit breakers only). This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT P, 1200A, 3 pole, circuit breaker has an interrupting rating of 50kA at 600VAC. The circuit breaker has a continuous current rating of 100% with an ABC phase connection. PowerPacT R circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose