Schneider Electric RLF36160U31A Molded Case Circuit Breaker 600V 1600A

(No reviews yet) Write a Review
SKU:
RLF36160U31A
UPC:
785901771722
Condition:
New
Mounting Mode:
unit mount busbar)
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
[Ics] Rated Service Breaking Capacity:
65 kA 240 V AC 50/60 Hz IEC 60947-2 || 45 kA 380/415 V AC 50/60 Hz IEC 60947-2
Product Name:
PowerPact R
Warranty:
18 months
Width:
16.53 in
Ambient Air Temperature For Storage:
-50-85 °C
Environmental Disclosure:
ENVPEP2206034EN
Ambient Air Temperature For Operation:
-25-70 °C
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Breaking Capacity Code:
L
Net Weight:
52 lb(US)
Awg Gauge:
AWG 3/0...750 kcmil aluminium/copper
Line Rated Current:
1600-1600 A
Halogen Content Performance:
Halogen free plastic parts product
Rohs Exemption Information:
Yes
Quality Labels:
CE
Pvc Free:
Yes
Device Application:
distribution
Circuit Breaker Application:
HACR rated
Trip Unit Technology:
electronic, standard, MicroLogic 3.0, LI
Depth:
14.49 in
Ip Degree Of Protection:
IP40
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Height:
16.24 in
Terminal Identifier:
AL2500RK
Electrical Connection:
busbar connection, line || busbar connection, load
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 voltage release MN or MX plug-in)
Mounting Support:
busbar
Pollution Degree:
3 IEC 60947-1
Mercury Free:
Yes
Product Or Component Type:
circuit breaker
Control Type:
operating handle
Range:
PowerPact
Local Signalling:
alarm 1 LED yellow)long-time pick up)
Quantity Per Set:
1
Utilisation Category:
category A
Suitability For Isolation:
yes IEC 60947-2
Product Certifications:
UL || CSA || NOM
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Circularity Profile:
ENVEOLI2206034EN
Standards:
UL || CSA || NEMA || NMX J-266 || IEC 60947-2
Poles Description:
3P
Trip Unit Name:
MicroLogic 3.0
Sustainable Offer Status:
Green Premium product
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Eu Rohs Directive:
Compliant with Exemptions
Wire Stripping Length:
35 mm
Continuous Current Rating:
0.8
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Breaking Capacity:
AIR 125 kA 240 V AC 50/60 Hz UL 489 || AIR 100 kA 480 V AC 50/60 Hz UL 489 || AIR 50 kA 600 V AC 50/60 Hz UL 489 || Icu 125 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 85 kA 380/415 V AC 50/60 Hz IEC 60947-2
Network Frequency:
50/60 Hz
Tightening Torque:
68-68 N.m 50-400 mm² (AWG 1/0...750 kcmil) || 68-68 N.m 50-150 mm² (2 x AWG 1/0...2 x 300 kcmil)
$38,266.50

Description

PowerPacT R-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT R-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Standard Trip with a 3.0 trip unit and an LI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT R circuit breakers are available in 2, 3, and 4-pole unit mount and I-Line construction (I-Line construction is available for 1000A and 1200A rated circuit breakers only). This unit has a busbar connection. This PowerPacT P, 1600A, 3 pole, circuit breaker has an interrupting rating of 50kA at 600VAC. The circuit breaker has a continuous current rating of 80%. PowerPacT R circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.