Schneider Electric RM17UAS14 Ov Or Uv 9..15Vdc 12Vdc 1C/O
Schneider Electric
$138.00
This Harmony RM17-U control relay allows monitoring of voltage control." "This modular control relay is ideal for monitoring of electrical values and voltage variation in industrial and building control panels." "It applies to a wide type of industrial automation applications such as hoisting, packaging, lifts, textile, water." "It has one of market slimmest form-factors with 17.5mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 1-pole DIN device." "It also offers a selectable memory function, integral LED for indicating control status, sealable cover, with simple and precise settings with screw trimmers." "It provides automatic shutdown management and fault information to user for a quick fault identification and troubleshooting." "Multi function controller for wide choice selected in hard-wired logic automated systems, ideal for refurbishment of old installations without using a PLC." 0 0 0 0 0 0 0 0 0
- Reset Time:
- 1500 ms time delay
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Overvoltage Category:
- III IEC 60664-1
- [Ui] Rated Insulation Voltage:
- 250 V IEC 60664-1 || 400 V IEC 60664-1
- Run-Up Delay At Power-Up:
- 1000 ms DC
- Switching Capacity In Va:
- 1250 VA
- Range Of Product:
- Harmony Control Relays
- Immunity To Microbreaks:
- 20 ms 12 V
- Hysteresis:
- 5-20 % threshold setting
- Measurement Error:
- < 1 % over the whole range with voltage variation || 0.2 %/°C with temperature variation
- Polarity:
- non reversible polarity on DC supply
- Ip Degree Of Protection:
- IP20 IEC 60529 terminals) || IP30 IEC 60529 casing)
- Maximum Switching Voltage:
- 250 V AC/DC
- Eu Rohs Directive:
- Pro-active compliance (Product out of EU RoHS legal scope)
- Nominal Output Current:
- 0.208333333333333
- Product Or Component Type:
- voltage control relay
- Time Delay Type:
- adjustable 0.1...10 s, 0 + 10 % Tt- time delay upon fault
- Pollution Degree:
- 3 IEC 60664-1
- Ambient Air Temperature For Operation:
- -20-50 °C
- Net Weight:
- 0.08 kg
- Mechanical Durability:
- 30000000 cycles
- Measurement Range:
- 9...15 V voltage DC
- Warranty:
- 18 months
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Non-Dissipating Shock Wave:
- 4 kV IEC 60255-5 || 4 kV IEC 60664-1 || 4 kV IEC 61000-4-5
- Relay Name:
- RM17UAS
- Product Specific Application:
- for single-phase and DC supply
- Relay Monitored Parameters:
- overvoltage or undervoltage detection || self-powered
- Directives:
- 73/23/EEC - low voltage directive || 89/336/EEC - electromagnetic compatibility
- Rohs Exemption Information:
- Yes
- Ambient Air Temperature For Storage:
- -40-70 °C
- Contacts Type And Composition:
- 1 C/O
- Operating Position:
- any position without derating
- Mounting Support:
- 35 mm symmetrical DIN rail conforming to IEC 60715
- Tightening Torque:
- 0.6-1 N.m IEC 60947-1
- Environmental Disclosure:
- ENVPEP1504008EN
- Relay Type:
- voltage control relay
- Operating Rate:
- <= 360 operations/hour full load
- Connections - Terminals:
- screw terminals, 1 x 0.5...1 x 4 mm² AWG 20...AWG 11) solid without cable end || screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end || screw terminals, 1 x 0.2...2 x 2.5 mm² AWG 24...AWG 12) flexible with cable end ||
- Supply Voltage Limits:
- 7-20 V DC
- Local Signalling:
- for power ON LED (green) || for relay ON LED (yellow)
- Utilisation Category:
- AC-12 IEC 60947-5-1 || AC-13 IEC 60947-5-1 || AC-14 IEC 60947-5-1 || AC-15 IEC 60947-5-1 || DC-12 IEC 60947-5-1 || DC-13 IEC 60947-5-1 || DC-14 IEC 60947-5-1
- Control Type:
- without test button
- Shock Resistance:
- 5 gn IEC 60068-2-27
- Product Certifications:
- CSA || C-tick || GL || UL || GOST
- Output Contacts:
- 1 C/O
- Electrical Durability:
- 100000 cycles
- Circularity Profile:
- ENVEOLI1504008EN
- Compatibility Code:
- RM17
- [Us] Rated Supply Voltage:
- DC self-powered
- Maximum Switching Current:
- 5 A AC/DC
- Vibration Resistance:
- 0.35 mm 5-57.6 Hz)IEC 60068-2-6 || 1 gn 57.6-150 Hz)IEC 60255-21-1
- Relative Humidity:
- 95-95 % 55-55 °C IEC 60068-2-30
- China Rohs Regulation:
- X
- Maximum Power Consumption In W:
- 1 W DC
- Electromagnetic Compatibility:
- emission standard for industrial environments conforming to IEC 61000-6-4 || emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3 || immunity for industrial environments conforming to NF EN/IEC 6
- Housing Material:
- self-extinguishing plastic
- Standards:
- IEC 60255-6
- Sustainable Offer Status:
- Green Premium product
- Minimum Switching Current:
- 10 mA 5 V DC
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Insulation Resistance:
- > 500 MOhm 500 V DC IEC 60255-5 || > 500 MOhm 500 V DC IEC 60664-1
- Quality Labels:
- CE
- Repeat Accuracy:
- +/- 0.5 % input and measurement circuit || +/- 1 % time delay
- Dielectric Test Voltage:
- 2 kV AC 50 Hz, 1 min IEC 60255-5 || 2 kV AC 50 Hz, 1 min IEC 60664-1
- Mercury Free:
- Yes
- Measurement Accuracy:
- +/- 10 % of the full scale value
- Width:
- 17.5 mm
- Catalog:
- View
- Datasheet:
- View