Schneider Electric RM17UAS15 Voltage Control Relay, Harmony Control Relays
Schneider ElectricThis Harmony RM17-U control relay allows monitoring of voltage control in single phase network. This modular control relay is ideal for monitoring of electrical values and voltage variation in industrial and building control panels. It applies to a wide type of industrial automation applications such as hoisting, packaging, lifts, textile, water. It has one of market slimmest form-factors with 17.5mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 1-pole DIN device. It also offers a selectable memory function, integral LED for indicating control status, sealable cover, with simple and precise settings with screw trimmers. It provides automatic shutdown management and fault information to user for a quick fault identification and troubleshooting. Multi function controller for wide choice selected in hard-wired logic automated systems, ideal for refurbishment of old installations without using a PLC.
- Sustainable Offer Status:
- Green Premium product
- Immunity To Microbreaks:
- 20 ms
- Power Consumption In Va:
- 0-3 VA AC
- Insulation Resistance:
- > 500 MOhm 500 V DC IEC 60255-5 || > 500 MOhm 500 V DC IEC 60664-1
- Repeat Accuracy:
- +/- 0.5 % input and measurement circuit || +/- 1 % time delay
- Directives:
- 89/336/EEC - electromagnetic compatibility || 73/23/EEC - low voltage directive
- Dielectric Test Voltage:
- 2 kV AC 50 Hz, 1 min IEC 60255-5 || 2 kV AC 50 Hz, 1 min IEC 60664-1
- Switching Capacity In Va:
- 1250 VA
- Pollution Degree:
- 3 IEC 60664-1
- Product Certifications:
- GL || UL || GOST || CSA || C-tick
- Local Signalling:
- for power ON LED (green) || for relay ON LED (yellow)
- Time Delay Type:
- adjustable 0.1...10 s, 0 + 10 % Tt- time delay upon fault
- Rohs Exemption Information:
- Yes
- Mounting Support:
- 35 mm symmetrical DIN rail conforming to IEC 60715
- Tightening Torque:
- 0.6-1 N.m IEC 60947-1
- Supply Voltage Limits:
- 50-270 V AC/DC
- Eu Rohs Directive:
- Pro-active compliance (Product out of EU RoHS legal scope)
- Connections - Terminals:
- screw terminals, 1 x 0.5...1 x 4 mm² AWG 20...AWG 11) solid without cable end || screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end || screw terminals, 1 x 0.2...2 x 2.5 mm² AWG 24...AWG 12) flexible with cable end ||
- Polarity:
- non reversible polarity on DC supply
- China Rohs Regulation:
- X
- Relay Monitored Parameters:
- overvoltage or undervoltage detection || self-powered
- Product Specific Application:
- for single-phase and DC supply
- Vibration Resistance:
- 0.35 mm 5-57.6 Hz)IEC 60068-2-6 || 1 gn 57.6-150 Hz)IEC 60255-21-1
- Electromagnetic Compatibility:
- emission standard for industrial environments conforming to IEC 61000-6-4 || emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3 || immunity for industrial environments conforming to NF EN/IEC 6
- Warranty:
- 18 months
- Compatibility Code:
- RM17
- Relative Humidity:
- 95-95 % 55-55 °C IEC 60068-2-30
- Control Type:
- without test button
- Shock Resistance:
- 5 gn IEC 60068-2-27
- Standards:
- IEC 60255-6
- Measurement Range:
- 65...260 V voltage AC/DC 50/60 Hz
- Mechanical Durability:
- 30000000 cycles
- Electrical Durability:
- 100000 cycles
- Circularity Profile:
- ENVEOLI1504008EN
- Output Contacts:
- 1 C/O
- Hysteresis:
- 5-20 % threshold setting
- Housing Material:
- self-extinguishing plastic
- Relay Type:
- voltage control relay
- Utilisation Category:
- AC-12 IEC 60947-5-1 || AC-13 IEC 60947-5-1 || AC-14 IEC 60947-5-1 || AC-15 IEC 60947-5-1 || DC-12 IEC 60947-5-1 || DC-13 IEC 60947-5-1 || DC-14 IEC 60947-5-1
- Operating Position:
- any position without derating
- Measurement Accuracy:
- +/- 10 % of the full scale value
- Maximum Switching Current:
- 5 A AC/DC
- Ip Degree Of Protection:
- IP20 IEC 60529 terminals) || IP30 IEC 60529 casing)
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Nominal Output Current:
- 0.208333333333333
- Measurement Error:
- < 1 % over the whole range with voltage variation || 0.2 %/°C with temperature variation
- Maximum Power Consumption In W:
- 1 W DC
- [Us] Rated Supply Voltage:
- self-powered
- Ambient Air Temperature For Storage:
- -40-70 °C
- Product Or Component Type:
- voltage control relay
- Quality Labels:
- CE
- Overvoltage Category:
- III IEC 60664-1
- Maximum Measuring Cycle:
- 150 ms measurement cycle as true rms value
- Range Of Product:
- Harmony Control Relays
- Environmental Disclosure:
- ENVPEP1504008EN
- Non-Dissipating Shock Wave:
- 4 kV IEC 60255-5 || 4 kV IEC 60664-1 || 4 kV IEC 61000-4-5
- Ambient Air Temperature For Operation:
- -20-50 °C
- Operating Rate:
- <= 360 operations/hour full load
- Width:
- 17.5 mm
- Run-Up Delay At Power-Up:
- 1000 ms DC || 500 ms AC
- Reset Time:
- 1500 ms time delay
- Contacts Type And Composition:
- 1 C/O
- Minimum Switching Current:
- 10 mA 5 V DC
- Mercury Free:
- Yes
- Relay Name:
- RM17UAS
- Net Weight:
- 0.08 kg
- Maximum Switching Voltage:
- 250 V AC/DC
- [Ui] Rated Insulation Voltage:
- 250 V IEC 60664-1 || 400 V IEC 60664-1
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Control Circuit Frequency:
- 50...60 Hz +/- 10 %
- Catalog:
- View
- Datasheet:
- View