Schneider Electric RM35JA31MW Oc Or Uc Relay 2..500Ma 24-240Vac/Dc
Schneider Electric
$148.00
This Harmony RM35-JA relay allows monitoring of current control in single phase networks. This modular multi function single phase current control relay is ideal for monitoring of electrical values in industrial and building control panels. It applies to a wide type of industrial automation applications such as hoisting, packaging, lifts, textile, water. It has one of market medium form-factors with 35mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 3-pole DIN device. It also offers a sealable cover, simple and precise settings with screw trimmers. It provides automatic shutdown management and fault information to user for a quick fault identification and troubleshooting. multi function controller for wide choice selected in hard-wired logic automated systems, ideal for refurbishment of old installations without using a PLC. 0 0 0 0 0 0 0 0 0 0 0 0
- Eu Rohs Directive:
- Pro-active compliance (Product out of EU RoHS legal scope)
- Maximum Measuring Cycle:
- 30 ms measurement cycle as true rms value
- Product Certifications:
- GL || CSA || GOST || UL || C-tick
- Control Circuit Frequency:
- 40...70 Hz +/- 10 %
- Electromagnetic Compatibility:
- emission standard for industrial environments conforming to IEC 61000-6-4 || emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3 || immunity for industrial environments conforming to NF EN/IEC 6
- Shock Resistance:
- 15 gn 11 ms IEC 60255-21-1
- Non-Dissipating Shock Wave:
- 4 kV IEC 60255-5 || 4 kV IEC 60664-1 || 4 kV IEC 61000-4-5
- Measurement Error:
- 0.05 %/°C with temperature variation || 1 by volt over the whole range with voltage variation
- Polarity:
- no DC
- Rohs Exemption Information:
- Yes
- Tightening Torque:
- 0.6-1 N.m IEC 60947-1
- Environmental Disclosure:
- ENVPEP1504008EN
- Control Type:
- without test button
- Immunity To Microbreaks:
- 50 ms
- Range Of Product:
- Harmony Control Relays
- Mounting Support:
- 35 mm symmetrical DIN rail conforming to IEC 60715
- Vibration Resistance:
- 0.35 mm 5-57.6 Hz)IEC 60068-2-6 || 1 gn 57.6-150 Hz)IEC 60255-21-1
- [Ui] Rated Insulation Voltage:
- 250 V IEC 60664-1
- Operating Rate:
- <= 360 operations/hour full load
- Connections - Terminals:
- screw terminals, 1 x 0.5...1 x 4 mm² AWG 20...AWG 11) solid without cable end || screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end || screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) flexible with cable end ||
- Switching Capacity In Va:
- 1250 VA
- Local Signalling:
- for power ON LED (green) || for relay ON LED (yellow)
- Ambient Air Temperature For Operation:
- -20-50 °C
- Relay Type:
- current control relay
- Output Contacts:
- 2 C/O
- Mechanical Durability:
- 30000000 cycles
- Net Weight:
- 0.13 kg
- Operating Position:
- any position without derating
- Resistance Across Terminals:
- 1 Ohm E2-M terminals || 5 Ohm E1-M terminals || 0.2 Ohm E3-M terminals
- Threshold Setting:
- 10...100 %
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Maximum Switching Current:
- 5 A AC
- Warranty:
- 18 months
- Utilisation Category:
- AC-12 IEC 60947-5-1 || AC-13 IEC 60947-5-1 || AC-14 IEC 60947-5-1 || AC-15 IEC 60947-5-1 || DC-12 IEC 60947-5-1 || DC-13 IEC 60947-5-1 || DC-14 IEC 60947-5-1
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Time Delay Type:
- adjustable 0.3...30 s, 0 + 10 % Tt- time delay upon fault || adjustable 1...20 s, 0 + 10 % Ti- inhibition time delay upon startup
- Standards:
- IEC 60255-6
- Circularity Profile:
- ENVEOLI1504008EN
- Minimum Switching Current:
- 10 mA 5 V DC
- Marking:
- CE : EMC 89/336/EEC || CE : 73/23/EEC
- Relay Monitored Parameters:
- overcurrent or undercurrent in window mode || overcurrent or undercurrent detection
- Repeat Accuracy:
- +/- 0.5 % input and measurement circuit || +/- 2 % time delay
- Product Or Component Type:
- current control relay
- Safety Reliability Data:
- MTTFd = 296.8 years || B10d = 270000
- Dielectric Test Voltage:
- 2 kV AC 50 Hz, 1 min IEC 60255-5 || 2 kV AC 50 Hz, 1 min IEC 60664-1
- Measurement Range:
- 2...500 mA AC/DC E2-M terminals || 2...20 mA E1-M terminals || 2...500 mA current || 50...500 mA E3-M terminals
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Electrical Durability:
- 100000 cycles
- Maximum Power Consumption In Va:
- 3.5 VA AC
- Ambient Air Temperature For Storage:
- -40-70 °C
- Supply Voltage Limits:
- 20.4-264 V AC/DC
- Sustainable Offer Status:
- Green Premium product
- Maximum Power Consumption In W:
- 0.6 W DC
- Mercury Free:
- Yes
- Relative Humidity:
- 95-95 % 55-55 °C IEC 60068-2-30
- [Us] Rated Supply Voltage:
- AC/DC non self-powered
- Hysteresis:
- 5-50 % threshold setting
- Overvoltage Category:
- III IEC 60664-1
- Measurement Accuracy:
- +/- 10 % of the full scale value
- Relay Name:
- RM35JA
- Insulation Resistance:
- > 500 MOhm 500 V DC between supply and relay output IEC 60255-5 || > 500 MOhm 500 V DC between measurement and relay output IEC 60664-1 || > 1 MOhm 500 V DC between supply and measurement IEC 60255-5 || > 500 MOhm 500 V DC between supply and relay ou
- Ip Degree Of Protection:
- IP20 IEC 60529 terminals) || IP30 IEC 60529 casing)
- Width:
- 35 mm
- Reset Time:
- 1500 ms time delay
- Nominal Output Current:
- 0.208333333333333
- Run-Up Delay At Power-Up:
- 0.3 s
- Housing Material:
- self-extinguishing plastic
- Contacts Type And Composition:
- 2 C/O
- Pollution Degree:
- 3 IEC 60664-1
- Maximum Switching Voltage:
- 250 V AC
- China Rohs Regulation:
- X
- Control Circuit Voltage Limits:
- 15 % + 10 % Un
- Contacts Material:
- cadmium free
- Catalog:
- View
- Datasheet:
- View