Schneider Electric RM35JA32MR Current Control Relay Rm35-Ja - Range 0,
Schneider Electric
$157.68
$1200 Minimum Order for Non-stock Items or $60 Addl Schneider Handling Fee Applies
This Harmony RM35-JA relay allows monitoring of current control in single phase networks. This modular multi function single phase current control relay is ideal for monitoring of electrical values in industrial and building control panels. It applies to a wide type of industrial automation applications such as hoisting, packaging, lifts, textile, water. It has one of market medium form-factors with 35mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 3-pole DIN device. It also offers a diagnostic button, sealable cover, simple and precise settings with screw trimmers. It provides automatic shutdown management and fault information to user for a quick fault identification and troubleshooting. multi function controller for wide choice selected in hard-wired logic automated systems, ideal for refurbishment of old installations without using a PLC. 0 0 0 0 0 0 0 0 0 0 0 0
- Immunity To Microbreaks:
- 50 ms
- Relay Monitored Parameters:
- overcurrent or undercurrent in window mode || overcurrent or undercurrent detection
- Local Signalling:
- for relay ON LED (yellow) || for power ON LED (green)
- Range Of Product:
- Harmony Control Relays
- Setting Accuracy Of Time Delay:
- 0.916666666666667
- Housing Material:
- self-extinguishing plastic
- Tightening Torque:
- 0.6-1 N.m IEC 60947-1
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Contacts Material:
- cadmium free
- Maximum Power Consumption In W:
- 1.5 W DC
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Relay Name:
- RM35JA
- Supply Voltage Limits:
- 20.4-264 V AC/DC
- Insulation Resistance:
- > 100 MOhm 500 V DC IEC 60255-27
- Electrical Durability:
- 100000 cycles
- Measurement Error:
- < 1 % over the whole range with voltage variation || 0.05 %/°C with temperature variation
- Resistance Across Terminals:
- 0.005 Ohm E3-M terminals || 0.015 Ohm E2-M terminals || 0.05 Ohm E1-M terminals
- Circularity Profile:
- ENVEOLI1504008EN
- Nominal Output Current:
- 0.333333333333333
- Electromagnetic Compatibility:
- immunity for residential, commercial and light-industrial environments conforming to IEC 61000-6-1 || immunity for industrial environments conforming to IEC 61000-6-2 || emission standard for industrial environments conforming to IEC 61000-6-4 || ele
- Threshold Setting:
- 10...100 %
- Minimum Switching Current:
- 10 mA 5 V DC
- Time Delay Drift:
- <= 0.05 % per degree centigrade depending permissible ambient air temperature || <= 1 % within the supply voltage range
- Maximum Power Consumption In Va:
- 3.5 VA
- Eu Rohs Directive:
- Pro-active compliance (Product out of EU RoHS legal scope)
- China Rohs Regulation:
- X
- Mechanical Durability:
- 10000000 cycles
- Pollution Degree:
- 3 IEC 60664-1 || 3 UL 508
- Rohs Exemption Information:
- Yes
- Relay Type:
- current control relay
- Hysteresis:
- 5-50 % adjustable threshold setting || 3-3 % fixed full scale for window mode
- Utilisation Category:
- AC-15 IEC 60947-5-1 || DC-13 IEC 60947-5-1 || AC-1 IEC 60947-4-1 || DC-1 IEC 60947-4-1
- Width:
- 35 mm
- Standards:
- IEC 60255-1
- Maximum Measuring Cycle:
- 100 ms measurement cycle as true rms value
- Output Contacts:
- 2 C/O
- Product Or Component Type:
- current control relay
- Time Delay Type:
- adjustable 0.1...30 s, +/- 10 % of the full scale value Tt- time delay upon fault
- Sustainable Offer Status:
- Green Premium product
- Environmental Characteristic:
- 3K3 C
- Measurement Range:
- 0.15...1.5 A AC/DC E1-M terminals || 0.5...5 A E2-M terminals || 1.5...15 A E3-M terminals || 150 mA...15 A current AC/DC 50/60 Hz
- Control Circuit Voltage Limits:
- 15 % + 10 % Un
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Contacts Type And Composition:
- 2 C/O
- Mounting Support:
- 35 mm DIN rail conforming to IEC 60715
- Ambient Air Temperature For Operation:
- -20-50 °C 60 Hz || -20-60 °C 50 Hz
- Maximum Switching Voltage:
- 250 V AC
- Ambient Air Temperature For Storage:
- -40-70 °C
- Control Type:
- with test button
- Relative Humidity:
- 93-97 % 25-55 °C IEC 60068-2-30
- Reset Time:
- 1500 ms at maximum voltage
- Insulation:
- between supply and measurement
- Response Time:
- <= 500 ms (on crossing the threshold)
- Setting Accuracy Of The Switching Threshold:
- +/- 10 % of the full scale
- Repeat Accuracy:
- +/- 0.5 % input and measurement circuit || +/- 2 % time delay
- Internal Input Resistance:
- 0.015 Ohm || 0.005 Ohm || 0.05 Ohm
- Ip Degree Of Protection:
- IP20 IEC 60529 terminals) || IP50 IEC 60529 front panel) || IP30 IEC 60529 housing)
- Switching Threshold Drift:
- <= 0.05 % per degree centigrade depending permissible ambient air temperature || <= 1 % within the supply voltage range
- Safety Reliability Data:
- MTTFd = 296.8 years || B10d = 270000
- Dielectric Test Voltage:
- 2.5 kV AC 50 Hz, 1 min IEC 60255-27
- Net Weight:
- 0.12 kg
- [Us] Rated Supply Voltage:
- AC/DC non self-powered
- Product Certifications:
- CE || GL || CCC || EAC || RCM || UL || CSA
- Vibration Resistance:
- 0.075 mm 10-58.1 Hz) not in operation IEC 60068-2-6 || 1 gn 10-58.1 Hz) not in operation IEC 60068-2-6 || 0.035 mm 58.1-150 Hz) in operation IEC 60068-2-6 || 0.5 gn 58.1-150 Hz) in operation IEC 60068-2-6
- Switching Capacity In Va:
- 2000 VA
- Run-Up Delay At Power-Up:
- 0.3 s
- Mercury Free:
- Yes
- Connections - Terminals:
- screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end || screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end || screw terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end |
- Overvoltage Category:
- III IEC 60664-1 || III UL 508
- Shock Resistance:
- 15 gn 11 ms) not in operation IEC 60068-2-27 || 5 gn 11 ms) in operation IEC 60068-2-27
- Environmental Disclosure:
- ENVPEP1504008EN
- Maximum Switching Current:
- 8 A AC
- Catalog:
- View
- Datasheet: