This Harmony XB5, monolithic analog timer can be set for timing intervals between 3 to 60 minutes and is supplied with a 24V DC input. This analog timer provides visual timing of your processes. It is easily installed into standard 22mm diameter cut-outs and connected with simple screw-clamp connections. It is impact resistant, dust resistant, water resistant and vibration resistant thanks to its IP65, making it ideal for operation in harsh environments. It provides highly visible timing of machine processes, ensuring accuracy and consistency of operation.
- Temperature Drift:
- +/- 0.05 %/°C
- Minimum Switching Current:
- 10 mA
- Height:
- 62 mm
- [Ui] Rated Insulation Voltage:
- 50 V IEC 60947-1 || 50 V IEC 60664-1
- Setting Accuracy Of Time Delay:
- +/- 10 % of full scale 25 °C IEC 61812-1
- Shape Of Signaling Unit Head:
- round
- Device Presentation:
- monolithic product
- Overvoltage Category:
- class 3 IEC 60536 || class 3 IEC 60664-1
- Mounting Diameter:
- 22 mm
- Shock Resistance:
- +/- 15 gn 11 ms 6 shocks on each axis)IEC 60068-2-27
- Diameter:
- 29 mm
- Local Signalling:
- LED green, flashing timing in progress || LED, steady no timing in progress and output relay energised
- [Us] Rated Supply Voltage:
- 24 V DC
- Rohs Exemption Information:
- Yes
- Connections - Terminals:
- screw terminals 1 x 4 mm² IEC 60947-1 || screw terminals 1 x 2.5 mm² IEC 60947-1
- Reset Time:
- 5 ms after time delay on de-energisation || 7 ms during time delay on de-energisation
- Sale Per Indivisible Quantity:
- 1
- Environmental Disclosure:
- ENVPEP1710010EN
- Dielectric Strength:
- 1500 V IEC 61812-1
- Product Certifications:
- UL Listed || CE
- Time Delay Range:
- 3...60 min
- Eu Rohs Directive:
- Pro-active compliance (Product out of EU RoHS legal scope)
- Line Rated Current:
- 200 mA at 20 °C( derating 1.5 mA per °C)
- Time Delay Type:
- A
- Maximum Residual Current:
- 0.1 mA
- Ambient Air Temperature For Storage:
- -20-80 °C
- Resistance To Electromagnetic Fields:
- 10 V/m 80 MHz...1 GHz level 3 IEC 61000-4-3 || 3 V/m 1.4...2 GHz level 2 IEC 61000-4-3 || 1 V/m 2...2.7 GHz level 1 IEC 61000-4-3
- Output Type:
- open collector PNP
- Range Of Product:
- Harmony XB5
- Pollution Degree:
- 3 IEC 60664-1
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Circularity Profile:
- ENVEOLI1710010EN
- Temporary Permissible Current:
- 10 A 0.01 s
- Surge Withstand:
- 1 kV, level 2 IEC 61000-4-5
- [Uimp] Rated Impulse Withstand Voltage:
- 4 kV IEC 60947-1 || 4 kV IEC 60664-1
- Output Short-Circuit Protection:
- yes
- Mercury Free:
- Yes
- Protection Type:
- reverse polarity protection || overvoltage protection
- Net Weight:
- 0.027 kg
- Thickness:
- 1-6 mm
- Disturbance Radiated/Conducted:
- class B EN 50022
- Power Consumption In W:
- 1 W
- Immunity To Radioelectric Fields:
- 10 V level 3 IEC 61000-4-6
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other repr
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Sustainable Offer Status:
- Green Premium product
- Resistance To Fast Transients:
- 2 kV level 3 IEC 61000-4-4
- Ambient Air Temperature For Operation:
- -20-60 °C
- Tightening Torque:
- 0.5 N.m
- Fixing Collar Material:
- plastic
- Product Or Component Type:
- timer
- Vibration Resistance:
- 0.15 mm 10-60 Hz)IEC 60068-2-6 || 2 gn 60-150 Hz)IEC 60068-2-6
- China Rohs Regulation:
- X
- Voltage Drift:
- +/- 0.2 %/V
- Supply Voltage Limits:
- 16.8-31.2 V DC
- Bezel Material:
- plastic
- Ip Degree Of Protection:
- front IP65 IEC 60529 || back IP20 IEC 60529
- Electromagnetic Compatibility:
- electrostatic discharge 6 kV level 3 conforming to IEC 61000-4-2 || electromagnetic emission class B conforming to IEC 55011
- Maximum Voltage Drop:
- 3 V
- Standards:
- UL 508 || IEC 61812-1
- Repeat Accuracy:
- +/- 0.5 %
- Datasheet: