Schneider Electric XB5DTGM2 Panel Mounted Timer Monofunction 0,5S To

(No reviews yet) Write a Review
SKU:
XB5DTGM2
UPC:
3606481205506
Condition:
New
Vibration Resistance:
0.15 mm 10-60 Hz)IEC 60068-2-6 || 2 gn 60-150 Hz)IEC 60068-2-6
Connections - Terminals:
screw terminals 1 x 4 mm² IEC 60947-1 || screw terminals 1 x 2.5 mm² IEC 60947-1
Sustainable Offer Status:
Green Premium product
Resistance To Fast Transients:
2 kV level 3 IEC 61000-4-4
Shock Resistance:
+/- 15 gn 11 ms 6 shocks on each axis)IEC 60068-2-27
Electromagnetic Compatibility:
electrostatic discharge 6 kV level 3 conforming to IEC 61000-4-2 || electromagnetic emission class B conforming to IEC 55011
Ip Degree Of Protection:
front IP65 IEC 60529 || back IP20 IEC 60529
[Ui] Rated Insulation Voltage:
250 V IEC 60947-1 || 250 V IEC 60664-1
Time Delay Range:
0.5...10 s
Rohs Exemption Information:
Yes
Overvoltage Category:
class 3 IEC 60536 || class 3 IEC 60664-1
Shape Of Signaling Unit Head:
round
Diameter:
29 mm
Pollution Degree:
3 IEC 60664-1
Repeat Accuracy:
+/- 0.5 %
Protection Type:
overvoltage protection
Output Short-Circuit Protection:
no
Time Delay Type:
A
Output Type:
thyristor
Height:
62 mm
Bezel Material:
plastic
Net Weight:
0.027 kg
[Us] Rated Supply Voltage:
110...230 V AC/DC
Immunity To Radioelectric Fields:
10 V level 3 IEC 61000-4-6
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Ambient Air Temperature For Storage:
-20-80 °C
Ambient Air Temperature For Operation:
-20-60 °C
Dielectric Strength:
1500 V IEC 61812-1
Standards:
IEC 61812-1 || UL 508
Sale Per Indivisible Quantity:
1
Temporary Permissible Current:
10 A 0.01 s
Surge Withstand:
2 kV, level 3 IEC 61000-4-5
Local Signalling:
LED green, steady timing in progress || LED, off no timing in progress and output relay energised
Fixing Collar Material:
plastic
Power Consumption In W:
1 W
Mounting Diameter:
22 mm
Maximum Residual Current:
5 mA
[Uimp] Rated Impulse Withstand Voltage:
4 kV IEC 60947-1 || 4 kV IEC 60664-1
Voltage Drift:
+/- 0.2 %/V
Supply Voltage Limits:
93.5-253 V AC/DC
Product Or Component Type:
timer
Thickness:
1-6 mm
Mercury Free:
Yes
Product Certifications:
CE || UL Listed
China Rohs Regulation:
X
Tightening Torque:
0.5 N.m
Resistance To Electromagnetic Fields:
10 V/m 80 MHz...1 GHz level 3 IEC 61000-4-3 || 3 V/m 1.4...2 GHz level 2 IEC 61000-4-3 || 1 V/m 2...2.7 GHz level 1 IEC 61000-4-3
Setting Accuracy Of Time Delay:
+/- 10 % of full scale 25 °C IEC 61812-1
Reset Time:
30 ms after time delay on de-energisation || 60 ms during time delay on de-energisation
Device Presentation:
monolithic product
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Power Consumption In Va:
1.5 VA
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Range Of Product:
Harmony XB5
California Proposition 65:
WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other repr
Circularity Profile:
ENVEOLI1710010EN
Temperature Drift:
+/- 0.05 %/°C
Minimum Switching Current:
10 mA
Disturbance Radiated/Conducted:
class B EN 50022
Environmental Disclosure:
ENVPEP1710010EN
Maximum Voltage Drop:
5 V
  • Schneider Electric XB5DTGM2 Panel Mounted Timer Monofunction 0,5S To
  • Schneider Electric XB5DTGM2 Panel Mounted Timer Monofunction 0,5S To
$49.50

Description

This Harmony XB5, monolithic analog timer can be set for timing intervals between 0.5 to 10 seconds and is supplied with a 100V to 240V AC/DC input. This analog timer provides visual timing of your processes. It is easily installed into standard 22mm diameter cut-outs and connected with simple screw-clamp connections. It is impact resistant, dust resistant, water resistant and vibration resistant thanks to its IP65, making it ideal for operation in harsh environments. It provides highly visible timing of machine processes, ensuring accuracy and consistency of operation.
View AllClose