Schneider Electric XPSOT3744 Ecc Press Module 230V Ac

(No reviews yet) Write a Review
SKU:
XPSOT3744
UPC:
3389110724769
Condition:
New
Depth:
118 mm
Ambient Air Temperature For Operation:
-10-55 °C
Ip Degree Of Protection:
IP10 terminals)IEC 60529 || IP40 enclosure)IEC 60529
Width:
200 mm
Sustainable Offer Status:
Green Premium product
Minimum Output Voltage:
17 V relay output
Minimum Output Current:
10 mA relay output
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Breaking Capacity:
180 VA holding AC-15 C300 relay output || 1800 VA inrush AC-15 C300 relay output
[Uimp] Rated Impulse Withstand Voltage:
4 kV III IEC 60647-5-1, DIN VDE 0110 part 1
Warranty:
18 months
Mercury Free:
Yes
[Ith] Conventional Free Air Thermal Current:
2.5 A
Product Certifications:
CSA || UL || TÜV
Number Of Terminal Blocks:
42
Power Consumption In Va:
12 VA
Mounting Support:
35 mm symmetrical DIN rail
Pvc Free:
Yes
Local Signalling:
4 LEDs
Function Of Module:
safety stop with automatic overtravel monitoring and control
Safety Module Application:
safety stop with automatic overtravel monitoring and control
Connections - Terminals:
captive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² with cable end || captive screw clamp terminals, 2 x 2.5 mm² without cable end
China Rohs Regulation:
X
Enclosure Material:
polycarbonate
Associated Fuse Rating:
4 A gG relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200
Supply Frequency:
50/60 Hz
Maximum Response Time On Input Open:
20 ms
Standards:
IEC 60947-5-1 || IEC 692 || IEC 60204-1
Environmental Disclosure:
ENVPEP1408008EN
Net Weight:
1.1 kg
Output Type:
relay, 3 NO, volt-free
Number Of Additional Circuits:
4 solid state outputs
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
[Us] Rated Supply Voltage:
230 V AC - 15...10 %
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Enclosure Type:
removable
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Range Of Product:
Preventa Safety automation
Product Or Component Type:
Preventa safety module
Ambient Air Temperature For Storage:
-25-85 °C
[Ui] Rated Insulation Voltage:
300 V 2)IEC 60647-5-1, DIN VDE 0110 part 1
Rohs Exemption Information:
Yes
Safety Reliability Data:
MTTFd = 60.9 years ISO 13849-1 || DC = 0...99 % ISO 13849-1 || PFHd = 1.33E-8 1/h IEC 62061
Circularity Profile:
ENVEOLI1408008EN
Safety Level:
can reach PL e/category 4 ISO 13849-1 || can reach SILCL 3 IEC 62061
Safety Module Name:
XPSOT
Input Protection Type:
internal, electronic
Height:
73 mm
Breaking Capacity:
10 mA 48 V solid state output circuit || 20 mA 24 V solid state output circuit || 1.5 A 24 V DC-13)50 ms relay output
Catalog:
View
Datasheet:
View
$1,320.00