Schneider Electric XPSPVK3784 Discordance Mod 230V Ac
SKU:
XPSPVK3784
UPC:
3389110727951
MPN:
Condition:
New
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Width:
152 mm
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Number Of Terminal Blocks:
32
[Us] Rated Supply Voltage:
230 V AC - 15...10 %
Safety Module Name:
XPSPVK
[Uimp] Rated Impulse Withstand Voltage:
4 kV III IEC 60647-5-1, DIN VDE 0110 part 1
Associated Fuse Rating:
4 A gG relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200
Supply Frequency:
50/60 Hz
Maximum Response Time On Input Open:
40 ms
Range Of Product:
Preventa Safety automation
Standards:
IEC 692 || IEC 60204-1 || IEC 60947-5-1
Mounting Support:
35 mm symmetrical DIN rail
Circularity Profile:
ENVEOLI1408008EN
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Breaking Capacity:
10 mA 48 V solid state output circuit || 20 mA 24 V solid state output circuit || 1.5 A 24 V DC-13)50 ms relay output
Mercury Free:
Yes
Environmental Disclosure:
ENVPEP1408008EN
[Ui] Rated Insulation Voltage:
300 V 2)IEC 60647-5-1, DIN VDE 0110 part 1
Safety Module Application:
for dynamic monitoring of double-bodied solenoid valves
Enclosure Material:
polycarbonate
[Ith] Conventional Free Air Thermal Current:
2.5 A
Number Of Additional Circuits:
4 solid state outputs
Product Certifications:
UL || CSA || TÃV
Depth:
118 mm
Minimum Output Current:
10 mA relay output
Rohs Exemption Information:
Yes
Product Or Component Type:
Preventa safety module
Output Type:
relay, 1 NO transfer function + 1 NC feedback loop, volt-free
Safety Level:
can reach PL e/category 4 ISO 13849-1 || can reach SILCL 3 IEC 62061
Breaking Capacity:
180 VA holding AC-15 C300 relay output || 1800 VA inrush AC-15 C300 relay output
ClimaSys CV Fanbox without grille and filter 230V 50Hz or 60Hz. 72 W 50 Hz, 88 W 60 Hz. Free flow rate with standard filter of 562 m3/h at 50 Hz and 586 m3/h at 60 Hz. 350 Pa flow rate 0 m³/h. 223 x...
ClimaSys CC Electronic hygrotherm. Display type by OLED screen. 200V AC to 240 V AC. 85 x 56 x 44 mm. Optional NTC external sensor. Electrical connection by 8 connectors 2.5mm². Mounting mode by...