Schneider Electric XPSUS12AP Safety Module Us Cat.4 24V Screw
Schneider Electric
$404.48
This safety relay is designed for monitoring Emergency stop, Guard switch, Magnetic switch, Proximity safety switch, PNP sensor, RFID safety switch, Safety light curtain, Two hand control station or Enabling switch. The safety relay is powered with 24V AC/DC, and equipped with a screw removable terminal block. This universal safety module embeds pre-defined safety functions, or selectable safety functions via rotary selectors. This safety relay embeds 2 safety inputs, 3 ON/OFF configurable pulsed outputs, 2 NO safety outputs, and 1 solid-state diagnostic output with complete status information. The maximum safety level achieved by this safety relay is PLe/Category 4 conforming to ISO 13849-1, SILCL 3 conforming to IEC 62061, SIL 3 conforming to IEC 61508. This safety relay weighs 0,200kg. Its dimensions are 22,5mm (Width) x 120mm (Depth) x 100mm (Height). This safety relay weighs 0,200kg. Its dimensions are 22,5mm (Width) x 120mm (Depth) x 100mm (Height). This safety relays is suitable for applications such as Food and Beverage, Hoisting, Material Handling, Material Working, Packaging. This safe relay conforms to IEC60947-5-1, IEC61508-1/2/3, ISO13849-1, IEC62061 functional safety standards, is certified by cULus, TÜV, EAC, CCC and KC marking. Harmony safety relays are compatible with Modicon logic controllers. This relay is mounted on a 35mm symmetrical DIN rail. Harmony XPS Basic and Universal safety relays are the first choice for managing single safety functions easily, typically in machines of simple to medium complexity. Harmony XPS Universal is the first choice for a broad range of simple to mid-complex machines.
- Synchronisation Time Between Inputs:
- 0.5 s || 2 s || 4 s
- Mercury Free:
- Yes
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Input/Output Type:
- semiconductor pulsed diagnostic output 24 V DC, 20 mA Z1, not safety-related
- Maximum Line Resistance:
- 500 Ohm
- Eu Rohs Directive:
- Pro-active compliance (Product out of EU RoHS legal scope)
- Function Of Module:
- emergency stop button with 2 NC contacts || guard monitoring with 1 or 2 limit switches || monitoring 2 PNP sensors || magnetic switch monitoring || light curtain monitoring || RFID switch || monitoring of electro-sensitive protection equipment (ESPE
- Ambient Air Temperature For Storage:
- -25-85 °C
- Maximum Response Time On Input Open:
- 20 ms
- Standards:
- IEC 60947-5-1 || IEC 61508-1 functional safety standard || IEC 61508-2 functional safety standard || IEC 61508-3 functional safety standard || IEC 61508-4 functional safety standard || IEC 61508-5 functional safety standard || IEC 61508-6 functional
- Environmental Disclosure:
- ENVPEP1811003EN
- Width:
- 22.5 mm
- Mounting Support:
- 35 mm symmetrical DIN rail
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Ip Degree Of Protection:
- IP20 terminals)IEC 60529 || IP40 housing)IEC 60529 || IP54 mounting area)IEC 60529
- Product Or Component Type:
- safety module
- Rohs Exemption Information:
- Yes
- Product Certifications:
- TÃV || cULus
- Safety Level:
- can reach PL e/category 4 ISO 13849-1 || can reach SILCL 3 IEC 62061 || can reach SIL 3 IEC 61508
- Circularity Profile:
- ENVEOLI1811003EN
- [Ie] Rated Operational Current:
- 5 A AC-1 for normally open relay contact || 3 A AC-15 for normally open relay contact || 5 A DC-1 for normally open relay contact || 3 A DC-13 for normally open relay contact || 3 A AC-1 for normally closed relay contact || 1 A AC-15 for normally clo
- Safety Module Name:
- XPSUS
- Sustainable Offer Status:
- Green Premium product
- Power Consumption In W:
- 2 W 24 V DC
- Auxiliary Contact Composition:
- 2 NO
- Input Protection Type:
- internal, electronic
- China Rohs Regulation:
- X
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Range Of Product:
- Harmony Safety Automation
- Minimum Output Current:
- 10 mA relay output
- Height:
- 100 mm
- Connections - Terminals:
- removable screw terminal block, 0.2...2.5 mm² solid or flexible || removable screw terminal block, 0.25...2.5 mm² flexible with ferrule single conductor || removable screw terminal block, 0.2...1.5 mm² solid or flexible twin conductor || removable
- Electrical Circuit Type:
- NC pair || PNP pair || antivalent pair || OSSD pair
- [Us] Rated Supply Voltage:
- 24 V AC - 15...10 % || 24 V DC - 20...20 %
- [Ith] Conventional Free Air Thermal Current:
- 0.333333333333333
- Net Weight:
- 0.200 kg
- Minimum Output Voltage:
- 12 V relay output
- Number Of Inputs:
- 2 safety input 24 V DC 5
- Safety Reliability Data:
- MTTFd > 30 years ISO 13849-1 || Dcavg >= 99 % ISO 13849-1 || PFHd = 1.13E-09 ISO 13849-1 || HFT = 1 IEC 62061 || PFHd = 1.13E-09 IEC 62061 || SFF > 99% IEC 62061 || HFT = 1 IEC 61508-1 || PFHd = 1.13E-09 IEC 61508-1 || SFF > 99% IEC 61508-1 || type =
- Number Of Outputs:
- 3 on/off configurable pulsed output
- Relative Humidity:
- 5-95 % non-condensing
- Local Signalling:
- for power ON LED (green) || for error LED (red) || for safety output status LED (yellow) || for start input LED (yellow) || for safety input S12 LED (yellow) || for safety input S13 LED (yellow) || for safety input S22 LED (yellow) || for safety inpu
- Input Compatibility:
- normally closed circuit ISO 14119 || XC limit switch ISO 14119 || mechanical contact ISO 14119 || normally closed circuit ISO 13850 || antivalent pair ISO 14119 || OSSD pair IEC 61496-1-2 || two-hand control EN 574/ISO 13851-III A || two-hand control
- [Ui] Rated Insulation Voltage:
- 250 V 2)IEC 60947-1
- Power Consumption In Va:
- 5.0 VA 24 V AC 50/60 Hz
- Associated Fuse Rating:
- 10 A gG NO relay output circuit IEC 60947-1
- Pvc Free:
- Yes
- Depth:
- 120 mm
- Safety Module Application:
- for electrical monitoring of two-hand control stations || monitoring antivalent contacts || for emergency stop, guard and light curtain monitoring || for enabling switch monitoring
- Type Of Start:
- automatic/manual/monitored
- [Uimp] Rated Impulse Withstand Voltage:
- 4 kV II IEC 60947-1
- Catalog:
- View
- Datasheet:
- View