Schneider Electric ZBE302 Single Contact Block, 1 Nc Monitoring
Schneider Electric
$45.44
This product is part of the Harmony XB4 and XB5 range, an offer of 22mm pushbuttons, switches and pilot lights. It is a single contact block with silver alloy contact. It is only used in combination with an emergency stop pushbutton and is not compatible with other pushbuttons. It comes with 1 NC monitoring contact with slow break operation. The NC contact is opened when the emergency stop is activated. The monitoring feature triggers emergency stop due to improper installation. It comes with CE, CCC, UKCA, EAC, UL and CSA certification. This monitoring contact is compatible for emergency stops in both the XB4 and XB5 range. It connects to control circuits with simple screw-clamp connections. The Harmony XB4 and XB5 range offers innovative features for simple and efficient use.
- Warranty:
- 18 months
- Product Or Component Type:
- contact block
- Cad Overall Width:
- 10 mm
- Eu Rohs Directive:
- Compliant
- Reach Free Of Svhc:
- Yes
- Net Weight:
- 0.013 kg
- Cad Overall Height:
- 41 mm
- Shock Resistance:
- 30 gn 18 ms) half sine wave acceleration IEC 60068-2-27 || 50 gn 11 ms) half sine wave acceleration IEC 60068-2-27 || 25 gn 6 ms) 1000 shocks on each axis IEC 60068-2-27
- Cad Overall Depth:
- 26 mm
- Mechanical Durability:
- 300000 cycles
- Device Presentation:
- basic element
- Short-Circuit Protection:
- 6 A cartridge fuse gG IEC 60947-5-1
- Mercury Free:
- Yes
- Toxic Heavy Metal Free:
- Yes
- [Uimp] Rated Impulse Withstand Voltage:
- 4 kV IEC 60947-1
- Mounting Of Block:
- front mounting
- Contact Block Type:
- single
- Operating Force:
- 5 N NC changing electrical state
- Vibration Resistance:
- 5 gn 10-500 Hz)IEC 60068-2-6 || 25 mm peak to peak 2-10 Hz)IEC 60068-2-6
- Ambient Air Temperature For Storage:
- -40-70 °C
- [Ui] Rated Insulation Voltage:
- 300 V 3)IEC 60947-1
- Standards:
- IEC 60947-1 || IEC 60947-5-1 || IEC 60947-5-4 || UL 60947-5-1 || CSA C22.2 No 60947-5-1 || JIS C8201-1 || JIS C8201-5-1 || GB/T 14048.5 || BS EN 60947-5-1 || GOST IEC 60947-5-1
- Electrical Reliability:
- λ < 10exp(-7) 5 V 1 mA in clean environment IEC 60947-5-4 || λ < 10exp(-8) 17 V 3.4 mA in clean environment IEC 60947-5-4
- Device Short Name:
- ZBE
- Product Certifications:
- CSA || EAC || BV || DNV || CE || LROS (Lloyds register of shipping) || CCC || UL Listed || CB Scheme || UKCA
- Protective Treatment:
- TH
- Reach Regulation:
- Free of Substances of Very High Concern above the threshold
- Operating Travel:
- 1.5 mm NC changing electrical state) || 4.3 mm total travel)
- Ip Degree Of Protection:
- IP20 IEC 60529
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Tightening Torque:
- 0.8-1.2 N.m IEC 60947-1
- [Ie] Rated Operational Current:
- 1.5 A 240 V, AC-15, B300 IEC 60947-5-1 || 3 A 120 V, AC-15, B300 IEC 60947-5-1 || 0.11 A 250 V, DC-13, R300 IEC 60947-5-1 || 0.22 A 125 V, DC-13, R300 IEC 60947-5-1
- Sale Per Indivisible Quantity:
- 5
- Shape Of Screw Head:
- cross pozidriv No 1 || slotted flat à 4 mm || slotted flat à 5.5 mm
- Range Of Product:
- Harmony XB4 || Harmony XB5
- Contacts Usage:
- monitoring contact
- [Ith] Conventional Free Air Thermal Current:
- 6 A IEC 60947-5-1
- Positive Opening:
- with IEC 60947-5-1 appendix K
- Connections - Terminals:
- screw clamp terminals, <= 2 x 1.5 mm² with cable end IEC 60947-1 || screw clamp terminals, >= 1 x 0.34 mm² without cable end IEC 60947-1
- Electrical Durability:
- 300000 cycles, AC-15, 2 A 230 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 300000 cycles, AC-15, 3 A 110 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 300000 cycles, AC-15, 3 A 24 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 300000 cycles, DC-13, 0.3
- Contacts Material:
- silver alloy (Ag/Ni)
- Contact Operation:
- slow-break
- Rohs Exemption Information:
- Yes
- China Rohs Regulation:
- X
- Ambient Air Temperature For Operation:
- -40-70 °C
- Contacts Type And Composition:
- 1 NC monitoring contact
- Catalog:
- View
- Datasheet:
- View