All five valve series are 2-port, normally closed pulse valves for compressed air. They differ in how they are fired, port range, and pressure and temperature limits. Specifications are from SMC catalogs.
| Series |
Fired by |
SMC port range |
Piping |
Max. pressure |
Fluid temperature |
| JSXF SMARTVENT |
Built-in solenoid and control board, 24 VDC |
3/4" to 2" |
Compression fitting, direct piping, immersion |
0.9 MPa (min. 0.1 MPa) |
-40 to 60°C |
| JSXFA |
External pilot valve |
3/4", 1", 1-1/2" |
Compression fitting (JSXFAE), direct piping (JSXFAF) |
0.9 MPa (min. 0.1 MPa) |
-40 to 60°C |
| JSXFAH |
External pilot valve |
3/4" to 2" |
Immersion, for 4" to 10" header tanks |
0.9 MPa (min. 0.1 MPa) |
-40 to 60°C |
| VXF2 |
Solenoid on the valve, external timer such as VXFC |
3/4" to 4" (20A to 100A) |
Direct piping, flange, flange body I and II |
0.7 MPa |
-10 to 60°C; -10 to 100°C high-temperature version |
| VXFA2 |
External pilot valve, 1/4 pilot port |
3/4" to 4" (20A to 100A) |
Direct piping, flange, flange body I and II |
0.7 MPa |
-10 to 60°C; -10 to 100°C high-temperature version |
JSXF SMARTVENT: Base and Remote Valves
Each SMARTVENT valve has a control board built in. Each group needs one base valve, which sets pulse ON time (100 to 234 ms), OFF interval (4 to 29 s), and firing order for up to 31 daisy-chained remote valves, 32 in all. SMC rates the JSXF for 10 million cycles or more, IP67 / NEMA 4.
- JSXFE / JSXFF: E = compression fitting (seals and washers included), F = direct piping (threaded)
- 06 / 10: 3/4" or 1" port. N = NPT
- 5: 24 VDC
- PBW / PRW: base board or remote board, M12 connector
- B: -40 to 60°C. -S = silencer included, -2 = electrical entry turned 180°
Air Operated: JSXFA and JSXFAH Part Numbers
Example: JSXFAE-14N-B-S1
- JSXFA E / F / H: E = compression fitting (seals and washers included), F = direct piping, H = immersion
- 14: port size (06 = 3/4", 10 = 1", 14 = 1-1/2", 20 = 2" on JSXFAH only)
- N: thread (R = Rc, N = NPT, F = G)
- B: fluid and ambient temperature -40 to 60°C
- S: silencer, shipped with the valve (port sizes 14 and 20 only)
- 1: 1/8 pilot port (blank = 1/4)
- A: made-to-order pilot valve orifice of Ø3 mm to under Ø5 mm (port sizes 06 and 10)
JSXFAH immersion valves add a header tank size after the series (4, 5, 6, 8, or 10 inch) and an OUT-port configuration code. For example, JSXFAH6-10R1-B is a 6-inch tank, 1" port, Rc thread, short OUT port without G thread. SMC supplies the immersion valve and pipe unassembled.
VXF2 and VXFA2 Part Numbers
Example: VXF21AAGB. VXFA2 air operated valves use the same code without the voltage letter, for example VXFA21AAB.
| Position |
Codes |
| Port size (digit after VXF2 / VXFA2) |
1 = 20A (3/4"), 2 = 25A (1"), 3 = 40A (1-1/2"), 4 = 50A (2"), 5 = 65A (2-1/2"), 6 = 80A (3"), 7 = 90A (3-1/2"), 8 = 100A (4") |
| Piping |
A = direct piping, B = flange, C = flange body I (flange mounting), D = flange body II (through-hole mounting) |
| Material / silencer |
A = NBR/POM, no silencer; B = NBR/POM with silencer; C = FKM/PTFE high temperature, no silencer; D = FKM/PTFE with silencer |
| Voltage / electrical entry (VXF2 only) |
Grommet A to E, DIN terminal F to L, conduit terminal M to R, conduit S to W, flat terminal Y, Z = special voltage or electrical option. Examples: G = 24 VDC DIN terminal with surge voltage suppressor; J = 110 VAC DIN terminal; S = 24 VDC conduit; U = 110 VAC conduit. |
| Thread (last letter) |
Blank = Rc, A = G thread, B = NPT thread |
JSXFM Enclosures and VXFC Controllers
JSXFM pilot valve enclosure: houses the pilot solenoid valves that fire air operated pulse valves such as the JSXFA. The enclosure comes in 6 or 8 stations, with 1 to 6 or 1 to 8 valves mounted and blanking plugs in unused stations. It is rated 24 VDC only, IP66 / NEMA 4, with Ø5 mm pilot valves at 18 W each. Options are a lid catch (A) and bracket (B).
VXFC dedicated controller: SMC's dedicated sequencer for the VXF2. VXFC06 has 6 outputs and VXFC10 has 10; cascade connection extends one system to 20 or 30. The suffix sets supply voltage: A = 85 to 240 VAC, D = 24 to 48 VDC. ON time is adjustable from 0.01 to 0.99 s and OFF interval from 0 to 299 s, with a dual pulse function and an external input to interrupt operation. Output voltage matches the supply voltage, so the valve coils must match the controller.
Ordering Mistakes to Avoid
- One SMARTVENT base per group. Order one base valve (PBW) and make the rest remotes (PRW). SMC does not allow a base to connect to another base.
- Undersized pilot valves. SMC recommends a pilot valve orifice of Ø5 mm or more for 3/4" and 1" JSXFA valves, and the valve may not operate correctly with less. For VXFA2, SMC specifies Ø5 mm or more on sizes 21 to 23 and Ø4 mm or more on sizes 24 to 28. Keep pilot tubing I.D. larger than the pilot orifice, 10 mm maximum.
- Pressure limits differ. JSXF and JSXFA valves are rated to 0.9 MPa. VXF2 and VXFA2 valves are rated to 0.7 MPa.
- Hot process air. Standard VXF2 / VXFA2 (NBR/POM, material code A or B) is rated to 60°C fluid temperature. Choose material code C or D (FKM/PTFE) for up to 100°C.
- Thread letter. VXF2 / VXFA2 part numbers ending in B are NPT. No final letter means Rc, and A means G.
- Controller voltage. A VXFC passes its supply voltage to the outputs, so a VXFC06D (24 to 48 VDC) needs DC coils and a VXFC06A (85 to 240 VAC) needs AC coils. Output current is 0.5 A or less per output.
- JSXFM power. Each pilot valve draws 18 W at 24 VDC. SMC recommends energizing no more than two at a time.
Dust Collector Valve FAQ
What is the difference between SMC JSXF and JSXFA pulse valves?
The SMC JSXF has a solenoid on the valve. The SMARTVENT version also has a built-in control board, so it needs no separate timer. The JSXFA is air operated: it has no coil and is fired by an external pilot valve, often mounted in a JSXFM enclosure. Both are rated 0.1 to 0.9 MPa and -40 to 60°C.
What does the SMC VXFC controller do?
The VXFC is SMC's dedicated controller for VXF2 dust collector valves. It fires 6 (VXFC06) or 10 (VXFC10) valves in sequence, with ON time from 0.01 to 0.99 s and OFF interval from 0 to 299 s. Boards can be cascaded to 20 or 30 outputs, and an external input can interrupt operation.
How large a dust collector valve does SMC make?
The SMC VXF2 and VXFA2 series cover 20A to 100A (3/4" to 4") ports, with direct piping, flange, and flange body versions. The JSXF and JSXFAH go up to 2" (50A), and the JSXFA compression and direct piping types go up to 1-1/2" (40A).
What pilot valve do I need for an air operated pulse valve?
SMC recommends a pilot valve orifice of Ø5 mm or larger for 3/4" and 1" JSXFA valves. A made-to-order A version accepts Ø3 mm to under Ø5 mm. The JSXFM enclosure uses Ø5 mm, 24 VDC pilot valves, and pilot tubing I.D. should be larger than the pilot orifice, 10 mm maximum.
Can SMC dust collector valves handle hot or cold process air?
The JSXF and JSXFA series are rated for fluid and ambient temperatures from -40 to 60°C, with no condensation. Standard VXF2 and VXFA2 valves are rated -10 to 60°C, and their FKM/PTFE high-temperature versions -10 to 100°C, with no freezing.
Do I need a silencer on a pulse valve?
Silencers are optional. On the JSXFA, an S in the part number means a silencer is shipped with the valve, available on 1-1/2" and 2" sizes. On the VXF2 and VXFA2, material codes B and D include a silencer.
Replacing pulse valves or laying out a new collector?
Send Automation Distribution your existing part numbers, header pressure, port size, piping style, and control voltage, and we'll match you to the right SMC valves, enclosures, and controllers.