Wago

WAGO 2002-1711/1000-836

(No reviews yet) Write a Review
SKU:
2002-1711/1000-836
MPN:
2002-1711/1000-836
Condition:
New
actuation type:
Push-in || Operating tool
approvals per:
UL 1059
type of fuse:
Cylindrical fuse 5 x 20 mm
color:
Gray
connectable conductor materials:
Copper
connection technology:
Push-in CAGE CLAMP«
country of origin sales organisation germany:
DE
depth from upper edge of din rail:
57.6 mm / 2.268 inch
design:
Horizontal type
fine stranded conductor:
0.25 ƒƒ‡ª 4 mm / 22 ƒƒ‡ª 12 AWG
fine stranded conductor with ferrule push in termination:
1 ƒƒ‡ª 2.5 mm / 18 ƒƒ‡ª 14 AWG
fine stranded conductor with insulated ferrule:
0.25 ƒƒ‡ª 2.5 mm / 22 ƒƒ‡ª 14 AWG
fire load:
0.242 MJ
flammability class per ul94:
V0
height:
76.8 mm / 3.024 inch
insulation material:
Polyamide (PA66)
legend ratings:
(III / 3) ƒƒ«ƒƒ– Overvoltage category III / Pollution degree 3
marking level:
Center/side marking
mounting type:
DIN-35 rail
nominal cross section:
2.5 mm
nominal voltage iii 3:
250 V
note conductor cross section:
Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination.
note on rated current 1:
Leakage current in case of a blown fuse: LED 2 mA
operation status indicator:
230 V
packaging type:
Box
rated current:
6.3 A
rated current ex e ii:
6.3 A
rated current ul use group b:
0.416666666666667
rated current ul use group c:
0.416666666666667
rated current ul use group d:
0.416666666666667
rated surge voltage iii 3:
6 kV
rated voltage en ex e ii:
230 V
rated voltage ul use group b:
250 V
rated voltage ul use group c:
250 V
rated voltage ul use group d:
250 V
ratings note:
Electrical ratings are given by the fuse and blown fuse indication.
ratings per:
ATEX: KIWA 17 ATEX 0030 U / IECEx: KIWA 17.0014U (Ex ec IIC Gc)
solid conductor:
0.25 ƒƒ‡ª 4 mm / 22 ƒƒ‡ª 12 AWG
solid conductor push in termination:
0.75 ƒƒ‡ª 4 mm / 18 ƒƒ‡ª 12 AWG
strip length:
10 ƒƒ‡ª 12 mm / 0.39 ƒƒ‡ª 0.47 inch
weight:
15.036 g
width:
6.2 mm / 0.244 inch
wiring direction:
Front-entry wiring
  • Wago 2002-1711/1000-836
  • Wago 2002-1711/1000-836
  • Wago 2002-1711/1000-836
$14.82

Description

TOPJOBS fuse disconnect terminal block; with pivoting fuse holder for 5 x 20 mm fuse; with blown fuse LED indication for 230 V; rail mount; 3-conductor; 6.2 mm wide; gray.

The WAGO 2002 TOPJOB S series feed-through terminal block is a gray, 1-deck unit with a fused-disconnect lever type for 5x20mm fuses, featuring a blown-fuse LED indicator for 230Vdc. It includes a built-in end plate, side/lateral and center marking slots, and is suitable for Ex e II applications. The terminal block supports 1 feed-through pole with 3 push-in wire connections (1+2 configuration) and accommodates wire sizes from 0.25mm² to 4mm² (#22AWG to #12AWG). It has a nominal cross-section of 2.5mm², a rated current of 6.3A, and uses Push-in CAGE CLAMP spring connections. The unit mounts on a DIN-35 rail (35 x 15 / 35 x 7.5) and has a width of 6.2mm, equivalent to part number 200217111000836.

View AllClose