null

WAGO 2002-3258

Wago
SKU:
20023258
$11.72
(No reviews yet) Write a Review
Condition:
New
Current Stock:
Triple-deck terminal block; shield/through/through (Shield/L/L); with marker carrier; rail mount; 2-conductor; 5.2 mm wide; gray.

The WAGO 2002 TOPJOB S series is a gray, triple-deck terminal block designed for feed-through and shield connections, featuring side and center marking slots with "Shield/L/L" markings. It accommodates 2 feed-through and 1 shield-through poles, supporting 3 push-in connections for each of the 2.5mm2 nominal cross-section wires, suitable for wire sizes ranging from 0.25mm2 to 4mm2 or #22AWG to #12AWG. The terminal block is rated for currents of 24A and 28A, utilizes Push-in CAGE CLAMP spring connections, and mounts on a DIN-35 rail with a width of 5.2mm, equivalent to model 20023258.

actuation type:
Push-in || Operating tool
approvals per:
C22.2 No 158
color:
Gray
connectable conductor materials:
Copper
connection technology:
Push-in CAGE CLAMP
country of origin sales organisation germany:
DE
depth from upper edge of din rail:
81.3 mm / 3.201 inch
design:
Horizontal type
fine stranded conductor:
0.25 4 mm / 22 12 AWG
fine stranded conductor with ferrule push in termination:
1 2.5 mm / 18 14 AWG
fine stranded conductor with insulated ferrule:
0.25 2.5 mm / 22 14 AWG
fire load:
0.326 MJ
flammability class per ul94:
V0
height:
93.3 mm / 3.673 inch
insulation material:
Polyamide (PA66)
legend ratings:
(III / 3) Overvoltage category III / Pollution degree 3
marking level:
Center/side marking
mounting type:
DIN-35 rail
nominal cross section:
2.5 mm
nominal voltage iii 3:
500 V
note conductor cross section:
Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination.
number of connection points:
3
number of connection points 2:
3
packaging type:
Box
rated current:
24 A
rated current 2:
28 A
rated current csa use group b:
20 A
rated current csa use group c:
20 A
rated current ul use group b:
20 A
rated current ul use group c:
20 A
rated current ul use group d:
0.208333333333333
rated surge voltage iii 3:
6 kV
rated voltage csa use group b:
600 V
rated voltage csa use group c:
600 V
rated voltage ul use group b:
300 V
rated voltage ul use group c:
300 V
rated voltage ul use group d:
600 V
ratings per:
IEC/EN 60947-7-1
solid conductor:
0.25 4 mm / 22 12 AWG
solid conductor push in termination:
0.75 4 mm / 18 12 AWG
strip length:
10 12 mm / 0.39 0.47 inch
weight:
20.356 g
width:
5.2 mm / 0.205 inch
wiring direction:
Front-entry wiring