actuation type: |
Push-in || Operating tool |
approvals per: |
CSA 22.2 No 158 |
color: |
Yellow |
connectable conductor materials: |
Copper |
connection technology: |
Push-in CAGE CLAMP® |
COUNTRY OF ORIGIN VKORG GERMANY: |
DE |
CUSTOMS TARIFF NUMBER VKORG GERMANY: |
85369010000 |
DEPTH FROM UPPER EDGE OF DIN RAIL: |
32.9 mm / 1.295 inches |
FINE STRANDED CONDUCTOR: |
0.5 ¢¦ 10 mm² / 20 ¢¦ 8 AWG |
FINE STRANDED CONDUCTOR WITH FERRULE PUSH IN TERMINATION: |
2.5 ¢¦ 6 mm² / 16 ¢¦ 10 AWG |
FINE STRANDED CONDUCTOR WITH INSULATED FERRULE: |
0.5 ¢¦ 6 mm² / 20 ¢¦ 10 AWG |
FIRE LOAD: |
0.222 MJ |
FLAMMABILITY CLASS PER UL94: |
V0 |
HEIGHT: |
73.3 mm / 2.886 inches |
INSULATION MATERIAL: |
Polyamide (PA66) |
LEGEND RATINGS: |
(III / 3) ¢ Overvoltage category III / Pollution degree 3 |
MARKING LEVEL: |
Center/side marking |
MATERIAL GROUP: |
I |
MEASUREMENT ERROR DEVIATION MAX FROM THE UPPER RANGE VALUE: |
MEASUREMENT ERROR DEVIATION MAX OF THE UPPER RANGE VALUE 2= |
MISMATING PROTECTION: |
MOUNTING NOTE= |
MOUNTING TYPE: |
DIN-35 rail |
NOMINAL CROSS SECTION: |
6 mm² |
NOMINAL VOLTAGE III 3: |
800 V |
NOTE CONDUCTOR CROSS SECTION: |
Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination. |
NOTE MATERIAL DATA: |
Information on material data can be found here |
POWER LOSS PER POLE POTENTIAL: |
1.3112 W |
PROCESSING TEMPERATURE: |
-35 ¢¦ +85 °C |
PRODUCT GROUP CODE: |
22 |
RATED CURRENT: |
41 A |
RATED CURRENT 2: |
57 A |
RATED CURRENT CSA USE GROUP B: |
50 A |
RATED CURRENT CSA USE GROUP C: |
50 A |
RATED CURRENT EX E II: |
36 A |
RATED CURRENT EX E II WITH JUMPER: |
33 A |
RATED CURRENT IN FOR SPECIFIED POWER LOSS: |
41 A |
RATED CURRENT UL USE GROUP B: |
50 A |
RATED CURRENT UL USE GROUP C: |
50 A |
RATED IMPULSE VOLTAGE III 3: |
8 kV |
RATED VOLTAGE CSA USE GROUP B: |
600 V |
RATED VOLTAGE CSA USE GROUP C: |
600 V |
RATED VOLTAGE EN EX E II: |
550 V |
RATED VOLTAGE UL USE GROUP B: |
600 V |
RATED VOLTAGE UL USE GROUP C: |
600 V |
RATINGS PER: |
IEC/EN 60947-7-1 |
REFERENCE HAZARDOUS AREAS: |
See installation notes in section ¢Knowledge¢ andDownloads ¢ Documentation ¢ Additional Information: Technical Section |
RESISTANCE VALUE FOR SPECIFIED CURRENT DEPENDENT POWER LOSS: |
0.00078 © |
SOLID CONDUCTOR: |
0.5 ¢¦ 10 mm² / 20 ¢¦ 8 AWG |
SOLID CONDUCTOR PUSH IN TERMINATION: |
2.5 ¢¦ 10 mm² / 14 ¢¦ 8 AWG |
STRIP LENGTH: |
13 ¢¦ 15 mm / 0.51 ¢¦ 0.59 inches |
WEIGHT: |
12.694 g |
WIDTH: |
7.5 mm / 0.295 inches |
WIRING DIRECTION: |
Front-entry wiring |